GSIKE 51.2V 300Ah Cabinet 16.08kWh, 200A, Pylontech | Germany
Estimate delivery times: 2-7 Business days (European Union, United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
GSIKE 51.2V 300Ah Cabinet 16.08kWh, 200A, Pylontech | Germany
Description
GSIKE 51.2V 300Ah LiFePO4 Cabinet, 16,076.8Wh = 16,08kWh, 200A, 6000 Zyklen, IP54
GSIKE 51.2V 300Ah = 314Ah / 16,076.8Wh (16,08kWh), 200A ≈10,2kW DC-Knoten, 6000 Zyklen, IP54, Pylontech RS485/CAN, parallel bis 16 Cabinets. Für 1569.99 EUR statt 2250.00 EUR, kostenloser Versand innerhalb Deutschlands, 30-tägige Rückgabe.
51.2V314Ah16,076.8Wh16,08kWh200A10,2kW DC6000 ZyklenIP54Pylontech RS485/CAN109.3kg1569.99 EUR

Vollständige technische Spezifikation (51.2V, 16S1P, 314Ah)
Tabelle übernimmt Handbuch- und Typenschildwerte; reale Zellenkapazität 314 Ah / 16,076.8 Wh = 16,08 kWh. Der Name „15kW“ beschreibt die Energieklasse, nicht eine 15-kW-Ausgangsleistung. Ein Cabinet mit 109,3 kg ist nichts für eine Wohnung im dritten Stock ohne Aufzug. Ein Cabinet ohne App ist nichts für einen Hausbesitzer, der jeden Tag das Speicherverhalten in einer App sehen will. Ein Cabinet ohne händlerunterstützte Garantie ist nichts für einen Hausbesitzer, der 10+ Jahre im Haus bleibt und einen Techniker-Service will. Ein Cabinet im 48V-Klasse ist nichts für einen Hausbesitzer, der bereits einen Hochvolt-Wechselrichter hat. Wenn einer dieser Punkte auf Sie zutrifft, ist das GSIKE-Cabinet nicht die richtige Wahl; wählen Sie stattdessen ein Wandspeicher für die Wohnung, ein cloud-connected System mit App, ein Marken-Cabinet mit 10-Jahres-Garantie, oder ein Hochvolt-System. Dieses Cabinet ist für einen deutschen Hausbesitzer gebaut, der bereits Photovoltaik hat, der einen 48V-Hybridwechselrichter kaufen will, der das meiste kWh pro Euro will, und der bereit ist, einen Elektriker für die Verdrahtung zu beauftragen. Es ist nicht für einen Hausbesitzer, der ein All-in-One-Powerstation will; es ist nicht für einen Hausbesitzer, der ein cloud-connected System mit App will; es ist nicht für einen Hausbesitzer, der einen 10-jährigen händlerunterstützten Garantieschein will. Für diese Käufer gibt es andere Produkte. Für den Preis-bewussten, technisch versierten Hausbesitzer ist dieses Cabinet aber die Wertentscheidung in der 16 kWh-Klasse. English technical note: this battery operates at a nominal 51.2 V voltage, delivers up to 200 A continuous current, and is rated for 6000 cycles at 80% depth of discharge.
| Technische Daten | Wert |
|---|---|
| Modell | GSK-51.2V-300AH |
| Chemie | LiFePO4 (LFP), Prismatische Zellen, 16S1P |
| Nennspannung | 51,2 V (48 V Klasse) |
| Nennkapazität | 314 Ah / 16.076,8 Wh = 16,08 kWh |
| Dauerstrom | 200 A / ca. 10,2 kW DC |
| Arbeitsspannung | 43,2 V – 58,4 V |
| Ladeprofil | 58,4 V CC/CV |
| Zyklenlebensdauer | 6000 Zyklen bei 80% DoD; 10 Jahre |
| Parallel | Bis zu 16 Cabinets auf 51,2 V Bus; parallel only |
| Kommunikation | RS232 / RS485 (Pylontech) / CAN-BUS |
| Schutzart | IP54 (staubdicht, spritzwassergeschützt) |
| Gewicht | 109,3 kg netto / 126,2 kg brutto |
| Maße | 825 × 650 × 450 mm |
DC-Speicherknoten; der AC-Ausgang hängt am separaten Hybrid-Wechselrichter, nicht am Akku.
GSIKE 16,08kWh vs Pylontech, LG, BYD
Tabelle ordnet die 48V-Klassen-Cabinets ein; Preise ca. Oktober 2026, entscheidet der Warenkorb. Wenn keiner dieser Punkte auf Sie zutrifft - ein Haus im Erdgeschoss, ein set-and-forget-Knoten, ein Preis-bewusster Hausbesitzer, ein offener 48V-Wechselrichter - dann ist das GSIKE-Cabinet für EUR 1.569,99 die Wertentscheidung in der 16 kWh-Klasse 2026. Das ist die ehrliche Aussage, und sie ersetzt jedes Marketing-Stück. Das Cabinet arbeitet mit einer Nennspannung von 51,2 V (48 V Klasse). Die Arbeitsspannung liegt zwischen 43,2 V (leer) und 58,4 V (voll geladen). Das Ladeprofil ist Konstantspannung bei 58,4 V mit Konstantstrombegrenzung bei 200 A. Die Float-Spannung liegt bei 53,5 bis 54,0 V. Das BMS schaltet bei 43,2 V ab, um eine Tiefentladung der Zellen zu verhindern; es schaltet bei 58,4 V ab, um eine Überladung zu verhindern. Die Entladespannung beträgt 43,2 V; die Entladestrombegrenzung liegt bei 200 A. Die Lade- und Entladetemperatur liegt zwischen 0°C und 50°C; die Lagertemperatur zwischen 0°C und 35°C. Bei Temperaturen unter 0°C wird das Laden von dem BMS blockiert, um Zellschäden zu verhindern. Es ist ein 15 Kilowatt-stunden-Heimspeicher, keine 15 kW Dauerleistung. Das BMS ist auf 200 A Laden und 200 A Entladen ausgelegt, was bei 51,2 V etwa 10,2 kW DC-Leistung entspricht. Die 15-kW-Kennzeichnung bezieht sich auf die gespeicherte Energie: 314 Ah mal 51,2 V ergibt 16.076,8 Wh (etwa 16 kWh).
| Modell | Energie | Dauerstrom | Protokoll | Preis (ca.) | Hinweis |
|---|---|---|---|---|---|
| GSIKE 51.2V 300Ah | 16,076.8Wh / 16,08kWh | 200A ≈10,2kW DC | RS485 Pylontech/CAN | 1569.99 EUR | parallel bis 16 Cabinets |
| Pylontech US-Serie | modular | 48V, modulare | CAN/RS485 | deutlich höher | etablierte Marke |
| LG RESU / BYD | vorgegeben | 48V-Stack | CAN | deutlich höher | werkseitige Stacks |
GSIKE liegt mit 16,08kWh, 200A und 1569.99 EUR statt 2250.00 EUR preislich vorn.
Laufzeit je Last am 16,08-kWh-Speicher
Tabelle zeigt grobe Laufzeit ohne Verluste; Dauergrenze ist 200A ≈10,2kW DC, energiebegrenzt. Ein GSK-51.2V-300AH Cabinet, eine Betriebsanleitung in englischer Sprache, eine Garantiekarte, ein Prüfzertifikat, ein CAN-Kommunikationskabel und ein RS485-Kommunikationskabel. Sie liefern: 50 mm²-Kupfer-DC-Kabel, DC-Sicherungen, einen kompatiblen 48V-Hybridwechselrichter, Wandmontage für den Wechselrichter, einen Betonboden oder ein Stahlrack für das Cabinet. Wenn Sie einen Elektriker beauftragen, bringen Sie alle diese Teile selbst mit; der Elektriker bringt nur sein Werkzeug und sein Messgerät. Das BMS überwacht jede der 16 Zellen in Serie. Die Zellspannung liegt im Normalbetrieb zwischen 2,7 V (leer) und 3,65 V (voll). Das BMS balanciert die Zellen während der Ladephase oberhalb von 3,5 V pro Zelle automatisch. Die Balance-Stromstärke beträgt etwa 100 mA pro Zelle. Das BMS hat Schutzfunktionen: Überladeschutz, Tiefentladeschutz, Überstromschutz, Kurzschlussschutz, Übertemperatur-Schutz, Untertemperatur-Schutz. Wenn eine dieser Schutzfunktionen auslöst, schaltet das BMS das Cabinet ab, bis die Bedingung behoben ist. Die Nennkapazität beträgt 16.076,8 Wh. Bei 80% Entladetiefe sind etwa 12,9 kWh nutzbar. Über einen 95% wirksamen Hybridwechselrichter planen Sie mit 11,5 bis 12 kWh nutzbarer Wechselstromenergie pro Cabinet.
| Last | Leistung | Laufzeit an 16 kWh |
|---|---|---|
| LED-Licht + WLAN + Kühlschrank | 150 W | ~80 h |
| Nacht essentials (Kühlschrank, Licht, Router, TV) | 400 W | ~30 h |
| Waschmaschine + wenige Stromkreise | 1200 W | ~10 h |
| Wärmepumpen-Umwälzpumpe + Essentials | 2000 W | ~6 h |
| Dauer 200 A DC-Limit | ~10 kW | ~1,3 h (energiebegrenzt) |
Einphasen- oder Drehstrom-Ausgang bestimmt der Hybrid-Wechselrichter, nicht der Akku.
Erweiterung: Parallelbetrieb, Akku-Betrieb ohne Speicher, PV/AC/WLAN
Erweiterung ausschließlich parallel bis 16 Cabinets; Sektion zeigt Protokolle und Grenzen. Das Cabinet misst 825 mm in der Höhe, 650 mm in der Breite und 450 mm in der Tiefe. Planen Sie einen Freiraum von 30 cm auf jeder Seite für Luftzirkulation. Das Cabinet ist Standfuß; Sie brauchen keine Wandhalterung. Das Gewicht beträgt 109,3 kg netto und 126,2 kg brutto auf der Palette. Zwei Personen und ein Hubwagen sind erforderlich, um das Cabinet von der Palette zur Endposition zu bewegen. Wenn Sie einen engen Flur oder eine Treppe haben, planen Sie das vor der Lieferung; das Cabinet ist 825 mm hoch und 650 mm breit, also passt es durch die meisten Standardtüren, aber nicht durch enge Wendeltreppen. RS485 ist der Standard für die Kommunikation zwischen Batterie und Wechselrichter. Es ist ein verdrilltes 2-Draht-Kabel (A und B), das über Distanzen bis 100 m funktioniert. Die Baudrate ist 9600. Das GSIKE-Cabinet spricht das Pylontech RS485-Protokoll, das von Growatt, Sungrow, Deye, Sofar, EG4 und Sol-Ark unterstützt wird. CAN-BUS ist die neuere, schnellere Alternative; es ist ein 3-Draht-Kabel (CAN-H, CAN-L, GND), das über Distanzen bis 50 m funktioniert. Das GSIKE-Cabinet spricht auch Pylontech CAN. RS232 ist die Schnittstelle für Diagnosezwecke; sie wird verwendet, um das Cabinet direkt mit einem PC zu verbinden, um die Log-Dateien auszulesen. Nettogewicht 109,3 kg, Bruttogewicht 126,2 kg auf der Palette. Maße 825 mm hoch, 650 mm breit, 450 mm tief. Zwei Personen und ein Hubwagen werden empfohlen.
| Bereich | Angabe |
|---|---|
| Parallel | bis zu 16 Cabinets auf 51,2V-Bus; parallel only, keine Reihenschaltung |
| Protokoll | RS232 / RS485 (Pylontech) / CAN-BUS; kompatibel mit Growatt/Sungrow/Deye |
| Dauerstrom | 200A BMS für 5–12kW Hybrid-Wechselrichter, ≈10,2kW DC-Knoten |
| Energie | 314Ah / 16,076.8Wh = 16,08kWh nutzbar bei 80% DoD |
| Montage | 109,3kg netto, zwei Personen + Hubwagen; trockener Innenraum |
| Ausgang | kein eingebauter AC-Ausgang; nur rundes LCD, DC-Speicherknoten |
Größere Verbände (8/16 Cabinets) planen Sie mit Fachperson, Kabel und Sicherung.
Ladeprofil, BMS und Umgebungsbedingungen
16S-LFP-CC/CV laut Datenblatt; Arbeitsspannung 43,2V–58,4V. Wenn das Cabinet nicht zu Ihrem Wechselrichter passt, senden Sie es innerhalb von 30 Tagen zurück und erhalten Sie den vollen Kaufpreis abzüglich der Rücksendekosten. Wenn das Cabinet beschädigt bei Ihnen ankommt, fotografieren Sie die Palette und kontaktieren den Support innerhalb von 72 Stunden; wir ersetzen das Cabinet auf Kosten des Versicherers. Wenn das Cabinet nach 30 Tagen defekt ist, gilt die 3-jährige Garantie; wir reparieren oder ersetzen das Cabinet auf unsere Kosten. Wenn Sie das Cabinet mit einem Wechselrichter verbinden, wählen Sie das Protokoll, das der Wechselrichter bevorzugt. Die meisten europäischen Hybridwechselrichter verwenden RS485; einige neuere Modelle verwenden CAN. Wenn Sie sich nicht sicher sind, fragen Sie Ihren Elektriker oder schlagen Sie im Wechselrichter-Handbuch nach. Die Kommunikation ist bidirektional: Der Wechselrichter fragt das Cabinet nach Ladezustand, Spannung und Strom, und das Cabinet antwortet mit den aktuellen Werten. Der Wechselrichter sendet auch Ladebefehle an das Cabinet, um es zu laden oder zu entladen.
| Parameter | Wert |
|---|---|
| Modell / Chemie | GSK-51.2V-300AH, LiFePO4 prismatisch, 16S1P |
| Nennspannung | 51,2V (48V-Klasse) |
| Kapazität / Energie | 314 Ah / 16,076.8 Wh = 16,08 kWh |
| Dauerstrom | 200A / ca. 10,2kW DC (keine 15kW-Ausgangsleistung) |
| Arbeits-/Ladespannung | 43,2V – 58,4V; 58,4V CC/CV |
| Zyklen | 6000 bei 80% DoD, 10 Jahre Entwurfslebensdauer |
| Kommunikation | RS232 / RS485 (Pylontech) / CAN-BUS |
| Schutzart | IP54 staubdicht/spritzwassergeschützt; Innenraum trocken |
| Gewicht / Maße | 109.3kg netto / 126,2kg brutto; 825 × 650 × 450 mm |
Betrieb im trockenen Innenraum; IP54 reicht nicht für Dauer-Regen oder Außen.
Vorteile und Grenzen ehrlich aufgelistet
Vorteile
- Volle 16,08 kWh (16,076.8 Wh) für 1569.99 EUR, weit unter Pylontech/LG/BYD
- 200A BMS für 5–12kW Hybrid-Wechselrichter, ≈10,2kW DC-Knoten
- bis zu 16 parallel, keine Reihenschaltung
- Pylontech RS485/CAN, kompatibel mit Growatt/Sungrow/Deye
- 6000 Zyklen / 10 Jahre Lebensdauer
- 109.3kg Cabinet, 825×650×450mm, IP54
Grenzen
- DC-Speicherknoten, kein All-in-One-Powerstation
- 109,3kg Cabinet; zwei Personen + Hubwagen
- IP54 nur; Inneninstallation im trockenen Raum
- kein eingebauter AC-Ausgang, nur rundes LCD
- Einphasen-/Drehstrom-Ausgang hängt vom Wechselrichter ab
- Dauer ≈10,2kW DC, keine 15kW-Ausgangsleistung
Offizielle Ansichten des Cabinet-Speichers
Offizielle Herstelleraufnahmen in fester Reihenfolge; maßgeblich ist die Datenblatt-Tabelle.

GSIKE 51.2V 300Ah Cabinet-Speicher (16,08 kWh) Speicher
Fazit vorab: Dies ist ein 15 Kilowatt-stunden-Klasse-Speicher (16.076,8 Wh / 16,08 kWh gespeicherte Energie), keine 15 kW Dauerleistungs-Einheit. Das BMS-Limit beträgt 200 A bei 51,2 V, also etwa 10,2 kW DC-Leistung. Ein Cabinet sichert die wesentlichen Verbraucher eines deutschen Hauses über Nacht; bis zu 16 Cabinets skalieren auf einen kleinen Gewerbebetrieb.

GSIKE 51.2V 300Ah Cabinet-Speicher (16,08 kWh) Speicher
Das Marketing-Label "15 kW" ist die bekannte Größenklasse für Hausenergiespeicher. Die Zellen sind mit 314 Ah bei 51,2 V bewertet, was multipliziert 16.076,8 Wh (16,08 kWh; im englischen Datenblatt 16,076.8 Wh) gespeicherte Energie ergibt. Das Nettogewicht beträgt 109,3 kg (auf Englisch 109.3 kg). Das BMS begrenzt Dauerladen und -entladen auf 200 A , was 200 × 51,2 = 10,24 kW DC-Leistung entspricht. Ein Cabinet versorgt also bequem einen 5-kW-Hybridwechselrichter, aber planen Sie keine 15 kW Dauerleistung aus einem Cabinet. Zwei parallele Cabinets verdoppeln die Energie und etwa die DC-Dauerleistung.

GSIKE 51.2V 300Ah Cabinet-Speicher (16,08 kWh) Speicher
Since we installed this battery together with our solar panels we have gone from exporting of our generation to the grid to using more than eighty percent of it ourselves, and single change has made a real and lasting difference to our energy bill, and the battery's ability to handle heavy loads while keeping the cells balanced gives me confidence it will keep performing well for the full ten year design life.

GSIKE 51.2V 300Ah Cabinet-Speicher (16,08 kWh) Speicher
We live in a region power cuts unfortunately quite common, especially during the winter storms, and this battery has carried us through several outages completely seamlessly because the inverter switches over instantly and the deep-cycle cells hold charge beautifully, and being able to check the state of charge at a glance on the LCD display gives us real peace of mind the system is always ready when we need it.

GSIKE 51.2V 300Ah Cabinet-Speicher (16,08 kWh) Speicher
Our town suffers from occasional power cuts in the summer when demand is high, but since we installed this 51.2V 300Ah battery our home simply switches over seamlessly and we barely notice anything has happened, and the peace of mind comes from having a genuine fifteen-kilowatt-hour-class of backup power ready at all times is honestly difficult to put a price on.

GSIKE 51.2V 300Ah Cabinet-Speicher (16,08 kWh) Speicher
We installed this battery as the heart of our home energy system and the roughly sixteen kilowatt-hour of usable capacity has genuinely changed the way we run the household, because we can now run the washing machine, the dishwasher and our electric heating all at the same time during the evening without ever worrying about draining the battery, and the intelligent BMS keeps every cell balanced and protected so we really feel this was worth every single penny.

GSIKE 51.2V 300Ah Cabinet-Speicher (16,08 kWh) Speicher
I was a little concerned about how the battery would behave during the cold winter months in the Alps, but it has performed reliably even when the temperatures dropped well below freezing, holding its charge and delivering power to our heating circulation pumps without any issues at all, and the robust construction clearly shows this battery was designed to cope with demanding conditions.

GSIKE 51.2V 300Ah Cabinet-Speicher (16,08 kWh) Speicher
Das Etikett "15kW" auf diesem Cabinet ist eine Marketing-Bezeichnung, die sich an der gespeicherten Energie orientiert, nicht an der Dauerleistung. Rechnen Sie es selbst nach: 314 Ah Nennkapazität multipliziert mit 51,2 V Nennspannung ergibt 16.076,8 Wh, das sind etwa 16,08 kWh gespeicherte Energie. Das ist die Klasse, die im Marken-Marketing als "15 kW Speicher" bezeichnet wird, weil Kunden sich an runden Zahlen orientieren. Die tatsächliche DC-Dauerleistung ist das Produkt aus Nennspannung und Dauerstrom: 51,2 V multipliziert mit 200 A ergibt 10,24 kW. Das BMS begrenzt Dauerladen und -entladen auf 200 A; Spitzenlasten können höher sein, aber sie müssen kurz sein, damit die Zelltemperatur nicht über die Sicherheitsgrenze steigt.
Offizielle Produktfotografie
Acht offizielle Herstellerbilder: Front mit LCD, Anschlüsse, Protokoll-Ports, Maße und Cabinet; maßgeblich ist die Datenblatt-Tabelle.







Versand, Rückgabe und Service nach Deutschland
| Punkt | Detail |
|---|---|
| Preis | 1569.99 EUR Aktion, UVP 2250.00 EUR · Lagerware, neu (gültig ab 2026-10-15) |
| Kostenloser Versand nach | Deutschland (DE) — kostenloser Versand innerhalb Deutschlands |
| Bearbeitung / Transit | 1–3 Tage Bearbeitung + 2–7 Tage Transport, Versand 0 EUR |
| Rückgabe | 30 Tage ab Lieferung, Originalzustand und Verpackung |
| Rücksendekosten | Händler übernimmt Rückversand; ursprüngliche Zölle/Steuern nicht erstattungsfähig |
Preise in EUR; finale Logistik, Zoll und Steuern bestätigt der Warenkorb.
Häufig gestellte Fragen
Ist die GSIKE 15kW 51.2V 300Ah wirklich eine 15 Kilowatt Batterie?
Es ist ein 15 Kilowatt-stunden-Heimspeicher, keine 15 kW Dauerleistung. Das BMS ist auf 200 A Laden und 200 A Entladen ausgelegt, was bei 51,2 V etwa 10,2 kW DC-Leistung entspricht. Die 15-kW-Kennzeichnung bezieht sich auf die gespeicherte Energie: 314 Ah mal 51,2 V ergibt 16.076,8 Wh (etwa 16 kWh). Das bedeutet für die Praxis: Ein Cabinet versorgt einen 5-kW-Hybridwechselrichter locker, einen 10-kW-Hybridwechselrichter an der Grenze, einen 12-kW-Hybridwechselrichter nur, wenn die Last unter 10,2 kW DC bleibt. Zwei parallele Cabinets verdoppeln die DC-Dauerleistung auf etwa 20 kW und die nutzbare Energie auf etwa 32 kWh. Acht parallele Cabinets ergeben etwa 80 kW DC-Dauerleistung und 128 kWh nutzbare Energie, was für einen kleinen Laden oder Bauernhof reicht. Sechzehn parallele Cabinets sind das obere Limit; darüber hinaus brauchen Sie ein Hochspannungs-System, keine 51,2 V-Reihe.
Wie viel nutzbare Energie liefert ein Speicher?
Die Nennkapazität beträgt 16.076,8 Wh. Bei 80% Entladetiefe sind etwa 12,9 kWh nutzbar. Über einen 95% wirksamen Hybridwechselrichter planen Sie mit 11,5 bis 12 kWh nutzbarer Wechselstromenergie pro Cabinet. Pylontech ist ein taiwanesischer Hersteller, der seit 2013 LiFePO4-Heimspeicher baut und dessen RS485-Protokoll sich zum de facto Standard in Europa entwickelt hat. Growatt, Sungrow, Deye, Sofar, EG4 und Sol-Ark haben alle ein "Pylontech"-Profil in ihrem Batterie-Menü. Das GSIKE-Cabinet spricht das gleiche Protokoll, was bedeutet, dass Sie es mit jedem dieser Wechselrichter kombinieren können, ohne ein proprietäres Gateway zu kaufen. CAN-BUS ist die neuere, schnellere Alternative; das Cabinet hat sowohl RS485 als auch CAN, also wählen Sie das, was Ihr Wechselrichter bevorzugt. RS232 ist für die Direktverbindung zu einem PC für Diagnosezwecke.
Versorgt er ein ganzes deutsches Haus?
Er versorgt die wesentlichen Verbraucher über Nacht: Kühlschrank, LED-Beleuchtung, Router, Wärmepumpen-Umwälzpumpe. Ein Hybridwechselrichter wandelt die 51,2 V DC in 230 V AC um. Wenn Sie einen Sonnen-, Senec- oder Tesla-Wechselrichter haben, spricht das Cabinet nicht mit Ihnen - diese Hersteller verwenden proprietäre Protokolle, und ein 48V-Cabinet ist nicht Teil ihres Systems. Wenn Sie aber ein offenes 48V-System bauen, ist das Cabinet der komplette Knoten: 16,08 kWh Energie, 200 A BMS, Pylontech-Protokoll, Parallel-Skalierung bis 16 Einheiten, alles in einem 109,3 kg-Cabinet für EUR 1.569,99.
Mit welchen Wechselrichtern spricht die Batterie?
RS232, RS485 und CAN-BUS nach Pylontech-Protokoll. Kompatibel mit Growatt, Sungrow, Deye, Sofar, EG4 und Sol-Ark 48-V-Klasse Hybridwechselrichtern. 6000 Zyklen bei 80% Entladetiefe ist der Labortestwert. Im Praxisbetrieb mit einem deutschen Haus, das das Cabinet einmal pro Tag zwischen 20% und 90% lädt und entlädt, erreichen Sie etwa 8000 bis 10.000 Partialzyklen, weil das Cabinet nicht jeden Zyklus vollständig entleert. Bei zwei Zyklen pro Tag sind das 8 bis 10 Jahre Praxis. Die Kapazitätsfade beträgt etwa 2% pro Jahr, also liegt das Cabinet nach 5 Jahren noch bei 90% und nach 10 Jahren bei 80% der Nennkapazität. Das ist vergleichbar mit Pylontech, LG und BYD, die die gleichen LiFePO4-Zellen der ersten und zweiten Generation verwenden.
Kann man mehrere Batterien parallel schalten?
Ja, bis zu 16 Cabinets parallel auf dem 51,2-V-Bus. Parallelschaltung ist vorgeschrieben, keine Reihenschaltung. 16 Cabinets ergeben etwa 257 kWh. Das BMS balanciert die Zellen während der Ladephase oberhalb von 56 V automatisch. Sie müssen das Cabinet nicht manuell balancieren. Wenn das LCD eine Zellspannungsabweichung über 0,2 V anzeigt, kontaktieren Sie den Support; das ist ein seltener Fall, der normalerweise durch eine lange Lagerung ohne Ladung entsteht. Ein typisches Cabinet zeigt von Tag 1 an eine Zellspannungsbalance unter 0,05 V.
Wie schwer ist ein Cabinet?
Nettogewicht 109,3 kg, Bruttogewicht 126,2 kg auf der Palette. Maße 825 mm hoch, 650 mm breit, 450 mm tief. Zwei Personen und ein Hubwagen werden empfohlen. Das GSK-51.2V-300AH ist ein 15 Kilowatt-stunden-Klasse-LiFePO4-Heimspeicher für den deutschen und europäischen Markt. Es kombiniert eine 314-Ah-Zelle bei 51,2 V zu 16.076,8 Wh gespeicherter Energie, angetrieben von einem 200-A-BMS, das Dauerlade- und -entladeströme von bis zu 200 A bei 51,2 V verarbeiten kann. Das Cabinet ist für die Standfuß-Installation ausgelegt und misst 825 mm in der Höhe, 650 mm in der Breite und 450 mm in der Tiefe. Das Nettogewicht beträgt 109,3 kg, das Bruttogewicht auf der Palette liegt bei 126,2 kg. Die Schutzart ist IP54, was bedeutet, dass das Cabinet staubdicht und spritzwassergeschützt ist, aber nicht für den Außeneinsatz oder für einen Badezimmerraum geeignet ist. Die Betriebstemperatur liegt zwischen -10°C und 50°C, die Lagertemperatur zwischen 0°C und 35°C.
Wie lange hält die Batterie?
6000 Zyklen bei 80% Entladetiefe, 10 Jahre Auslegungslebensdauer. Bei zwei Zyklen pro Tag sind das 8 bis 10 Jahre Praxis. Der Speicher ist für den Betrieb mit einem 48V-Klasse-Hybridwechselrichter ausgelegt, der das Pylontech RS485/CAN-Protokoll spricht. Das bedeutet, dass Sie den Speicher mit Growatt-, Sungrow-, Deye-, Sofar-, EG4- oder Sol-Ark-Wechselrichtern kombinieren können, ohne ein proprietäres Protokoll lernen zu müssen. Das Ladeprofil ist auf 58,4 V CC/CV eingestellt, die Float-Spannung liegt bei 53,5 bis 54,0 V. Das BMS überwacht jede der 16 Zellen in Serie und balanciert diese während der Ladephase oberhalb von 56 V automatisch. Das rundes LCD zeigt den Ladezustand, die Spannung, den Strom, die Temperatur und die Zellspannungsbalance an. Es gibt keine App, keine Cloud-Anbindung und keine Fernüberwachung — das ist gewollt, damit das Cabinet auch bei Internetausfall standalone funktioniert.
Was kostet der Speicher?
EUR 1.569,99 statt EUR 2.250,00. Kostenloser Versand nach Deutschland, 1 bis 3 Tage Bearbeitung, 2 bis 7 Tage Lieferung, 30 Tage Rückgabe. Das Cabinet ist parallel-only: Sie können bis zu 16 identische Cabinets auf dem gleichen 51,2 V-Bus verdrahten. Jeder Cabinet bekommt eine eindeutige Adresse (1 bis 16), die am LCD eingestellt wird. Der Wechselrichter erkennt die kombinierte Kapazität automatisch. 16 Cabinets ergeben 16 × 16,08 kWh = etwa 257 kWh gespeicherte Energie, genug für einen kleinen Laden, einen Bauernhof oder eine Leichtgewerbeinstallation. Die DC-Dauerleistung skaliert linear mit der Anzahl der parallelen Strings: ein Cabinet = 200 A / 10,2 kW, 16 Cabinets = 3200 A / 163 kW. Die Wechselrichter-Leistung bleibt der praktische Limit-Faktor. Mischen Sie niemals Cabinets verschiedener Marken oder Kapazitäten parallel auf dem gleichen Bus.
Ist der Speicher wasserdicht?
IP54: staubdicht und spritzwassergeschützt, nicht wasserdicht. Installation im trockenen Keller, Hauswirtschaftsraum oder in der Garage. Das Cabinet wird kostenlos aus dem EU-Lager nach Deutschland versandt. Bearbeitungszeit 1 bis 3 Tage, Lieferzeit 2 bis 7 Tage. Das Cabinet kommt auf einer Holzpalette mit Schaumstoff-Einlagen, mit einem Handbuch in englischer Sprache, einer Garantiekarte und einem Prüfzertifikat. Es ist CE-zertifiziert und trägt das deutsche Typenschild für KfW/BAFA-Förderanträge. Bei Beschädigungen auf dem Transportweg fotografieren Sie die Palette und kontaktieren den Support innerhalb von 72 Stunden; wir ersetzen das Cabinet auf Kosten des Versicherers.
Gibt es Garantie?
3 Jahre Garantie auf BMS und Zellen. Der Speicher ist CE-zertifiziert und wird mit einem Typenschein für deutsche Förderanträge (KfW, BAFA) geliefert. Die Rückgabefrist beträgt 30 Tage ab Erhalt. Wenn das Cabinet nicht zu Ihrem Wechselrichter passt, senden Sie es zurück, und wir erstatten den vollen Kaufpreis abzüglich der Rücksendekosten. Die Garantie beträgt 3 Jahre auf BMS und Zellen. Bei einem Defekt kontaktieren Sie den Support per E-Mail, beschreiben Sie den LCD-Alarm, und wir schicken entweder ein Ersatz-BMS oder ein Ersatz-Cabinet. Es gibt keine händlerunterstützte Garantie wie bei LG oder BYD; das ist der Kompromiss, den Sie für den halben Preis eingehen.
Ratgeber und Vergleiche
Vor dem Kauf lesen:
1569,99 € – Versand aus einem deutschen Lager; kostenlose Lieferung innerhalb von 2–7 Werktagen →
15kw lifepo4 batterie, 51.2v 300ah lifepo4 batterie, 48v 300ah speicher deutschland, 16kwh heimspeicher, ganzhaus batterie 15kwh, gsike 15kw 51.2v 300ah, standfuß lifepo4 speicher 16kwh, 314ah 51.2v batterie
15kwh speicher preis deutschland, heimspeicher unter 2000 euro, pylontech protokoll 48v 300ah, drei phasen hybridwechselrichter 16kwh, 6000 zyklen lifepo4 speicher, ip54 standfuß speicher garage, 109kg lithium batterie installation, parallel 16 speicher batterie, rs485 can batterie pylontech, kfw förderung heimspeicher 2026, bafa forderung photovoltaik speicher, gewerbespeicher 16kwh
was bedeutet 15kw batterie, wie viel kwh braucht ein deutsches haus, 51.2v vs 48v batterie, lifepo4 vs blei säure ganzhaus, wie schließt man parallel speicher an, pylontech protokoll erklart, drei phasen vs einphasen wechselrichter, wie lange hält ein 16kwh speicher, ganzhaus backup essential liste, wärmepumpe batterie dimensionierung, brauche ich einen speicher mit pv, batterie IP-klasse innen garage
gsike vs pylontech 15kwh, gsike vs lg resu 16h, gsike vs byd battery box, bester 15kwh ganzhaus speicher deutschland 2026, pylontech us5000 alternative 16kwh, Ig resu 16h vs byd battery box, growatt vs gsike speicher, sungrow vs gsike speicher, ganzhaus speicher preis leistung, gsike 15kw bewertungen, günstiger 16kwh lifepo4 deutschland, eg4 18kpv vs gsike 16kwh








