GSIKE FixWall 5.0: 51.2V 100Ah 5.12kWh Wall LiFePO4 Battery for Europe
Estimate delivery times: 2-7 Business days (European Union, United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
GSIKE FixWall 5.0: 51.2V 100Ah 5.12kWh Wall LiFePO4 Battery for Europe
Description
GSIKE FixWall 5.0: 51.2V 100Ah (5.12kWh) Wall LiFePO4 Battery for European Homes, With Built-in BMS
The GSIKE FixWall 5.0 is a wall-mounted 51.2V 100Ah LiFePO4 pack holding 5.12kWh, priced at €849.99 EUR with a struck price of €1,250.00, supplied as a battery-only DC node without AC output for pairing with a separate 230V 48V hybrid inverter.
Product Overview
This slim 48V-class LFP storage pack is intended for European households that store solar-generated or time-shifted energy on a wall bracket, then pass that DC reserve to a compatible hybrid inverter rather than converting to AC inside the pack itself.
Listed at €849.99 EUR, reduced from a €1,250.00 reference price; one variant, currently in stock. Complimentary delivery to 15 EU markets; 30-day return window; three-year warranty. Duties and taxes are non-refundable.
Battery and Electrical Specifications
Every electrical figure below follows the verified 100AH FixWall 5.0 record; the 3.2V LFP cells are assembled in a 16S1P arrangement and monitored by the built-in smart BMS.
| Specification | Detail |
|---|---|
| Chemistry and assembly | LiFePO4 3.2V cells, 16S1P (16 in series, 1 parallel) |
| Nominal voltage | 51.2 V (48V-class residential storage bus) |
| Capacity and energy | 100 Ah / 5120 Wh = 5.12 kWh |
| Continuous current | 50 A charge/discharge, equal to 2560 W; ordinary household loads should be planned around roughly 2.56 kW |
| Short-time current | 100 A = 5120 W, a short-time ceiling only; this level is not sustained |
| Working voltage | 43.2 V – 58.4 V; discharge cut-off near 43.2 V |
| Charge voltage | 58.4 V bulk/absorption, standard 16S LFP CC/CV profile |
| Built-in smart BMS | Over-charge, over-discharge, over-current, short-circuit, high and low temperature, surge-voltage protection |
| Communication ports | RS232, dual RS485 at 9600 bps, CAN-BUS at 500 kbps for closed-loop pairing with a compatible 48V hybrid inverter |
| Cycle life | 6000 cycles at 80% DoD @25°C; roughly 10-year design life |
| AC output | None; battery-only DC pack, paired with a separate 48V hybrid inverter |
| Monitoring | Round LCD display and power switch; no WiFi, Bluetooth, or phone application |
Expansion, Mounting and Housing
The pack expands in parallel only, hangs from a steel wall bracket, and sits inside an IP54-rated case intended for indoor or sheltered European installation spaces.
| Specification | Detail |
|---|---|
| Expansion topology | Parallel only, up to 16 units on the 51.2V bus for an 81.92 kWh bank (51.2V × 1600Ah); series stacking is not supported |
| Mixing rule | Do not combine brands or capacities within the same parallel bank |
| Mounting hardware | Steel wall bracket with expansion bolts; bracket about 409.5 × 322 mm |
| Terminals | Copper-alloy ring-lug terminals for fixed cabling |
| Housing and ingress | ABS/metal case, IP54 dust-tight and splash-proof; indoor or sheltered dry-room use |
| Certifications | CE, RoHS, UN38.3 |
| Operating temperature | −10°C to 50°C |
| Storage temperature | 0°C to 35°C; humidity below 95% RH, altitude under 2000 m |
| Low-temperature charging | No self-heating function; do not charge below 0°C |
| Net weight | 44 kg (44 ±2) |
| Dimensions | 640 H × 428 W × 160 D mm |
European Home Energy Context
Against high EU and UK electricity prices, a 5.12kWh pack shifts midday solar generation into the evening peak, supports time-of-use tariff arbitrage, and holds a reserve for essential circuits during a local power cut. Runtime depends on household load, inverter efficiency, and depth of discharge.
| Context Point | Detail |
|---|---|
| 230V pairing | The pack feeds a compatible 230V single-phase 48V hybrid inverter; inverter output, phase count, and backup switching are decided by that separate device |
| Self-consumption | Stored daytime PV covers evening cooking, lighting, and appliance loads instead of exporting excess generation at a lower export rate |
| Power-cut reserve | Essential circuits ride on the battery through a short interruption while the system waits for grid restoration |
| Retrofit fit | The 160 mm-deep case suits a narrow European home, garage, or utility-room wall beside the existing services |
In the Box
| Item | Included |
|---|---|
| FixWall 5.0 51.2V 100Ah battery pack | Yes |
| Wall mounting bracket and expansion bolts | Included |
| Power cable and communication cable | Included |
| User manual | Included |
| Hybrid inverter, solar panels, or mounting rails | Not included; chosen separately to match the installation |
Pros & Cons
Objective Strengths
- Useful reserve: The 5.12kWh 48V LFP pack covers evening self-consumption and essential-load backup in a European home.
- Communicating BMS: RS232, dual RS485, and CAN-BUS exchange charge and discharge limits with a compatible hybrid inverter.
- Long cycle life: 6000 cycles at 80% DoD @25°C, about a 10-year design life, and a three-year warranty.
- Expandable: Up to 16 parallel packs reach 81.92kWh as storage demand grows.
- Certified build: IP54 case with CE, RoHS, and UN38.3 certification for fixed indoor installation.
- Wall format: Bracket mounting and ring-lug terminals suit a compact garage or utility-room position.
Objective Weaknesses
- Battery only: No AC output on the pack; a separate 48V hybrid inverter is required to supply appliances.
- Continuous limit: The 50A rating equals 2560W sustained; the 100A / 5120W level is short-time only.
- No app: State of charge reads on the round LCD only; WiFi, Bluetooth, and phone control are absent.
- Parallel only: Higher-voltage series strings are unavailable, and packs of another brand or rating should not be wired into the same bank.
- No heater: The pack lacks any low-temperature warming element, and charging when the cells sit under 0°C must be avoided.
- Mounting weight: At 44kg the pack calls for two-person fitting and a structurally sound wall surface.
Real-World Scenarios
Typical European fixed-storage roles pair the 48V pack with an inverter in a residential, utility, or light-backup setting rather than using it as a portable source.
Garage Wall Storage
The pack hangs on an indoor garage wall where it stays dry and within cable run of the hybrid inverter.
Boiler Room Position
Placed with the home heating and electrical services, the bank holds reserve energy for outage support.
Inverter Communication Pairing
Wired over CAN or RS485, the BMS keeps charge voltage and discharge limits coordinated with the inverter.
Narrow Home Mount
The shallow 160mm case fits a spare indoor corner in a multi-storey or compact European residence.
Remote Cabin Reserve
Off-grid properties use the bank to hold daytime solar for evening and overnight consumption away from the grid.
Parallel Second Pack
A matching second unit joins in parallel when a household needs more stored energy than one pack provides.
Sheltered Fixed Install
Installation stays indoors or under cover, with clearance around the case for airflow and service access.
Frequently Asked Questions
What voltage, capacity, and energy does the GSIKE FixWall 5.0 hold?
It is a 51.2V nominal (48V-class) pack rated at 100Ah, storing 5120Wh equal to 5.12kWh, assembled from 3.2V LiFePO4 cells in a 16S1P configuration.
Does the battery run appliances directly from the wall pack?
No. The pack carries no AC output; it is a battery-only DC device that must connect to a separate 230V 48V hybrid inverter to supply household appliances.
Which 230V hybrid inverters can it communicate with?
The BMS exposes RS232, dual RS485, and CAN-BUS connections; verify that your chosen inverter speaks the matching Pylontech-compatible protocol and accepts the 58.4V charge profile before purchase.
How many packs can be connected in parallel?
Up to 16 packs may join on the 51.2V bus, forming an 81.92kWh bank. Series connection is not supported, and different brands or capacities must not be mixed together.
What continuous and short-time current can the 100Ah pack supply?
Rated continuous charge and discharge is 50A, equal to 2560W. The 100A figure equals 5120W and acts only as a short-time ceiling; that 100A level cannot be held continuously.
How many cycles and how long is the warranty?
The pack is rated for 6000 cycles at 80% DoD and 25°C, with a design life of about ten years, and it is covered by a three-year warranty.
Can it replace a 48V lead-acid solar battery?
It is a 48V-class LFP replacement for an older lead-acid solar bank, but first confirm your inverter sets the 58.4V bulk/absorption charge voltage and that the BMS communication protocol matches.
How and where is it mounted, and how heavy is it?
It hangs on a steel wall bracket secured with expansion bolts. Net weight is 44kg, and the case measures 640 H × 428 W × 160 D mm, with a round LCD, power switch, and copper-alloy ring-lug terminals, rated IP54 for indoor or sheltered use.
What protections does the built-in BMS provide?
The controller guards against over-charge, over-discharge, over-current, short-circuit, high and low temperature, and surge-voltage events, while balancing the cells inside the pack.
What temperature range applies, and can it charge in freezing weather?
Allowed ambient use runs from −10°C up to 50°C, with storage between 0°C and 35°C. The pack has no self-heating element, and charging at temperatures below 0°C is not permitted.
Related GSIKE European Guides
Work through self-consumption rates, evening peak pricing, and payback assumptions for a 5kWh wall pack across EU and UK tariff structures.
Compare the FixWall 5.0 against established CE-certified 5kWh wall options on format, communication, and warranty positioning.
Map evening household kWh and essential outage loads to the 5.12kWh reserve, and decide how much storage a typical European household needs.
Review wall-mount checks, communication wiring, charge-profile matching, and CE/IEC considerations for a European retrofit install.
51.2V 100Ah LiFePO4 battery, 48V 100Ah home battery, 5kWh wall mounted battery, 230V hybrid inverter battery, 48V 100Ah 5.12kWh LiFePO4 wall battery, GSIKE FixWall 5.0, 5kWh solar battery for European home, low-voltage 48V LFP battery for PV storage, wall-mounted LiFePO4 battery with BMS and CAN, 48V 100Ah battery for 230V solar hybrid inverter, evening self-consumption wall battery for EU home







