GSIKE FixWall 5.0 — 51.2V 100Ah (5.12kWh) Wall LiFePO4 Battery With Built-in BMS for Solar Self-Consumption and Outage Backup in Italian Homes
A wall-mounted GSIKE FixWall 5.0 stores 5.12kWh from a 51.2V 100Ah LFP battery, priced at €849.99 with a struck reference of €1,250.00. As a DC-only energy node it has no mains outlet of its own; through a separate 230V 48V hybrid inverter it keeps midday rooftop solar for the evening household load and an essential-circuit buffer when the Italian grid drops.
Product Overview
Mounted on its steel bracket next to the inverter, this compact 48V-class unit suits an Italian appartamento in an old town centre, a villa, a coastal second home or a country outbuilding. Inside the enclosure the energy stays on the DC side; alternating current is produced only by the external hybrid inverter. The stored 5.12kWh covers evening consumption drawn from the rooftop array and a short buffer for essential circuits during a mains interruption.
Buying price €849.99, reduced from the €1,250.00 struck figure; single variant, available now. Delivery within the 15 listed EU destinations is free, with order processing in 1–3 days and delivery in 2–7 days; returns are accepted for 30 days and the unit carries a three-year warranty. Import duties and taxes are not refundable. View the product: GSIKE 51.2V 100Ah LiFePO4 battery listing on gesike.com.
Battery and Electrical Specifications
The figures below come from the verified 100Ah FixWall 5.0 specification. Thirty-two-volt LFP cells are arranged 16S1P and watched over by the onboard smart BMS. The enclosure contains neither an AC outlet, a phone app nor a warming element.
| Specification | Detail |
|---|---|
| Chemistry and assembly | LiFePO4 3.2V cells, 16S1P (16 in series, one parallel string) |
| Nominal voltage | 51.2V, the 48V-class residential storage bus used with Italian 48V inverters |
| Capacity and energy | 100Ah / 5120Wh = 5.12kWh |
| Continuous current | 50A charge/discharge, equal to 2560W; plan ordinary household loads around roughly 2.56kW |
| Short-time current | 100A = 5120W, a brief ceiling only; this level is not held continuously |
| Working voltage | 43.2V – 58.4V; discharge cut-off near 43.2V |
| Charge voltage | 58.4V bulk/absorption, standard 16S LFP CC/CV profile |
| Built-in smart BMS | Guards against over-charge, over-discharge, over-current, short-circuit, high and low temperature, and surge voltage |
| Communication ports | RS232, dual RS485 at 9600 bps, CAN-BUS at 500 kbps for closed-loop pairing with a compatible 48V hybrid inverter |
| Cycle life | 6000 cycles at 80% DoD @25°C; design life roughly ten years |
| AC output | None; battery-only DC pack, paired with a separate 48V hybrid inverter |
| Monitoring | Round LCD and power switch; no WiFi, Bluetooth or phone application |
Expansion, Mounting and Housing
Additional packs are added in parallel rather than in series; the unit hangs from its steel wall bracket inside an IP54 enclosure built for a dry indoor or covered space. In Italy's warm, dry summers and mild winters, a ventilated mounting spot keeps the cabinet free of condensation.
| Specification | Detail |
|---|---|
| Expansion topology | Parallel only, up to 16 units on the 51.2V bus for an 81.92kWh bank (51.2V × 1600Ah); series stacking is not supported |
| Mixing rule | Do not combine brands or capacities within the same parallel bank |
| Mounting hardware | Steel wall bracket with expansion bolts; bracket about 409.5 × 322 mm |
| Terminals | Copper-alloy ring-lug terminals for fixed cabling |
| Housing and ingress | ABS/metal case, IP54 dust-tight and splash-proof; indoor or sheltered dry-room use |
| Certifications | CE, RoHS, UN38.3 |
| Operating temperature | −10°C to 50°C |
| Storage temperature | 0°C to 35°C; humidity below 95% RH; altitude under 2000 m |
| Low-temperature charging | No self-heating function; do not charge below 0°C |
| Net weight | 44kg (44 ±2) |
| Dimensions | 640 H × 428 W × 160 D mm |
Italian Home Energy Context
Stored at midday from rooftop panels, the 5.12kWh reserve carries the household through the evening peak instead of exporting surplus at a lower rate, and leaves an essential-load buffer for a local cut in supply. How long the buffer lasts depends on what is connected, how efficiently the inverter converts and how deeply the pack is discharged. The DC bus feeds a matched single-phase 230V 48V hybrid inverter; that external device decides the AC output, phase arrangement and backup switching.
| Context Point | Detail |
|---|---|
| 230V pairing | A matched single-phase 230V 48V hybrid inverter draws from the pack and forms the AC supply for appliances around the home |
| Rooftop self-consumption | Daylight generation held in the pack runs evening cooking, lights and small appliances rather than being sold back at an export tariff |
| Outage reserve | During a brief mains drop, priority circuits stay on battery until supply returns |
| Historic-city placement | At 160mm deep, the case fits a tight old-town appartamento, a villa stair cupboard or a country outbuilding next to the incoming services |
| Climate placement | Warm Mediterranean conditions call for a ventilated indoor or covered location away from rain, dust and direct sun |
In the Box
| Item | Included |
|---|---|
| FixWall 5.0 51.2V 100Ah battery pack | Yes |
| Wall mounting bracket and expansion bolts | Included |
| Power cable and communication cable | Included |
| User manual | Included |
| Hybrid inverter, solar panels or mounting rails | Not included; chosen separately to match the installation |
Pros & Cons
Objective Strengths
- Evening buffer: 5.12kWh of LFP storage covers after-dark consumption and priority loads around an Italian dwelling.
- Talks to the inverter: RS232, twin RS485 and CAN-BUS lines hand charge and discharge limits to the matched hybrid unit.
- Durable cycling: 6000 cycles to 80% depth of discharge at 25°C, roughly a ten-year design horizon, backed by a three-year warranty.
- Room to grow: sixteen matching packs in parallel bring the bus to 81.92kWh if storage needs rise.
- Marked enclosure: IP54 housing carrying CE, RoHS and UN38.3 marks for fixed indoor mounting.
- Space-saving wall fit: bracket fixing and ring-lug terminals suit a small garage, cupboard or services room.
Objective Weaknesses
- DC side only: no mains outlet inside the case; appliances require an external 48V hybrid inverter.
- Current ceiling: 50A (2560W) is the sustained band; 100A / 5120W appears only as a short peak that cannot be held.
- No remote app: the round LCD shows state of charge; WiFi, Bluetooth and phone control are not provided.
- Parallel wiring only: series strings cannot be built, and unlike brands or ratings must not share a bank.
- No heating strip: there is no cell warming element, and charging below 0°C must be avoided.
- Lift weight: at 44kg the pack calls for two-person handling and a structurally sound wall.
Real-World Scenarios
These fixed-storage applications pair the 48V pack with an inverter in homes, service rooms or light backup roles; the unit is not a portable power source.
Technical-Room Wall Mount
Fixed to a dry internal wall beside the inverter and consumer unit, the pack keeps DC runs short and accessible in a villa or town-house utility room.
Heated Services Room
Next to the heating circuit and electrical intake, the bank stands ready to support a cooler-season interruption.
Inverter Communication Pairing
A CAN or RS485 link lets the BMS align charge voltage and discharge cut-off with what the inverter expects.
Narrow Old-Town Apartment
Its 160mm depth tucks into an unused indoor corner of a small historic-centre appartamento with little floor area.
Country Home and Second-Home Reserve
A rural casa, casale or holiday property draws on held daytime solar for evening and overnight household use.
Parallel Second Pack
When one pack cannot cover the requirement, an identical second unit joins the same bus.
Sheltered Fixed Install
The mount remains indoors or under cover, leaving airflow and service clearance around the enclosure.
Frequently Asked Questions
What voltage, Ah rating and stored energy does the FixWall 5.0 offer?
The 48V-class bus runs at a nominal 51.2V; the 100Ah cells hold 5120Wh, or 5.12kWh, in a 16S1P LiFePO4 build.
Will the wall pack power Italian appliances without another device?
No. There is no mains outlet in the case: this is a DC-only unit, and an external 230V 48V hybrid inverter must form the AC supply before appliances can run.
Which hybrid inverters exchange data with the battery on an Italian site?
Data passes through RS232, twin RS485 and CAN-BUS. Check beforehand that the target inverter supports the matching Pylontech-compatible protocol and the 58.4V charge curve.
What is the parallel pack limit on one 51.2V bus?
Sixteen matching packs can share one 51.2V bus for an 81.92kWh bank. Series wiring is not allowed, and mixed brands or ratings must not be bundled together.
Which continuous and short-time current limits does the 100Ah wall pack observe?
Sustained charge/discharge sits at 50A, or 2560W. The 100A / 5120W mark is a brief ceiling only and cannot be held.
How many cycles is the pack rated for, and for how long is it warranted?
It is rated for 6000 cycles at 80% depth of discharge and 25°C, with a roughly ten-year design life, and is covered by a three-year warranty.
Is it a drop-in 48V lead-acid replacement for an existing Italian PV setup?
It can substitute for an old 48V lead-acid solar bank, as long as the inverter uses the 58.4V bulk/absorption voltage and the BMS protocol matches.
How is the wall pack mounted indoors, and what are its weight and case size?
A steel bracket anchored with expansion bolts carries the unit. It weighs 44kg net in a 640 × 428 × 160 mm case, with round LCD, power switch and copper-alloy ring-lug terminals; IP54 for indoor or sheltered placement.
Which events does the pack's smart BMS guard against?
Monitoring covers over-charge, deep discharge, over-current, short circuit, temperature extremes and surge voltage, with internal cell balancing handled by the controller.
What are the permitted ambient and storage temperatures, and may charging start under 0°C?
Operating ambient spans −10°C to 50°C; storage should stay between 0°C and 35°C. No warming strip is fitted, and charging under 0°C is disallowed.
Related GSIKE Guides for Italy
Self-consumption rates, evening household draw and reserve assumptions for a 5kWh wall pack under Italian electricity conditions.
Format, communication and warranty positioning of the FixWall 5.0 beside established CE-certified 5kWh rivals.
Evening kWh and essential outage loads matched against the 5.12kWh reserve, to size storage for a typical Italian dwelling.
Wall-mount checks, comms wiring, charge-profile matching and CE/IEC points for an Italian retrofit.
51.2V 100Ah LiFePO4 battery, 48V 100Ah home battery, 5kWh wall mounted battery, 230V hybrid inverter battery, 48V 100Ah 5.12kWh LiFePO4 wall battery, GSIKE FixWall 5.0, 5kWh solar battery for an Italian home, low-voltage 48V LFP battery for PV storage, wall-mounted LiFePO4 battery with BMS and CAN, 48V 100Ah battery for a 230V solar hybrid inverter, evening self-consumption wall battery for Italy, 5kWh backup pack for appartamento, villa and country home