GSIKE 12.8V 300AH Lithium Energy Storage Battery for Solar Power System
Estimate delivery times: 2-7 Business days (European Union, United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
GSIKE 12.8V 300AH Lithium Energy Storage Battery for Solar Power System
Description
GSIKE 12.8V 300Ah LiFePO4 Battery 4019.2Wh, 100A, 1280W Ceiling, 6000 Cycles | 369.99 EUR
Final Verdict: GSIKE 12.8V 300Ah = 314Ah engineering cells, 4019.2Wh energy, 100A BMS with a 1280W continuous ceiling (400A pulse only), 6000 cycles @80% DoD, IP65, parallel-expandable. At 369.99 EUR instead of 470.00 EUR, free delivery to 15 EU countries, 30-day returns and warranty.
12.8V314Ah4019.2Wh1280W ceiling100A6000 cycles80% DoDIP6526kg369.99 EUR

Full technical specification (GSK-12.8V-300AH)
Manual and rating-plate figures; engineering cells are 314Ah / 4019.2Wh, the '300Ah' tier nameplate ≈ 3840Wh. At the 3840Wh nameplate divided by the load: 100W → 38.4h, 300W → 12.8h, 500W → 7.68h, 800W → 4.8h and 1000W → 3.84h. Keep every continuous load at or below the 1280W ceiling; at the full ceiling the bank lasts ~3.0–3.14h. When running through a separate 12V inverter, derate by about 90–95% efficiency and leave depth-of-discharge headroom. The pack weighs 26kg net (27kg gross) — plan a two-person lift. The price is €369.99 EUR struck from €470.00 (21% off, Save €100.01), in stock and new. Shipping is free to 15 European countries (1–3 days handling plus 2–7 days transit), with 30-day returns by post. The warranty is 3 years against a ~10-year design life, so the covered period is shorter than the expected service life at light use. Connecting the inverter to the grid and generator has a precise procedure and switch order. Always isolate the input branches first, then connect battery, panel and AC circuit, and finally set the charge profile and parameters. Off-grid and backup mode require a clean output waveform and fast transfer time; sensitive electronics, computers and network gear need a stable wave without oscillation. Have all work checked by a qualified electrician if you do not hold the relevant competence. Safety rules for an isolated installation: never work live, protect every branch against short circuit and sparks, protect the battery against overcharge and deep discharge, and do not exceed the continuous output limit. A pure sine wave protects sensitive electronics but does not replace correct cable and fuse sizing. If you are unsure of the wiring or battery profile, use a qualified installer; a wrong install endangers equipment and safety.
| Parameter | Value |
|---|---|
| Chemistry / nominal voltage | LiFePO4 (LFP), 12.8 V nominal (4 cells in series) |
| Rated capacity / energy | 314 Ah / 4019.2 Wh (12.8V × 314Ah engineering cells); "300Ah" tier nameplate ≈ 3840 Wh |
| Continuous current | 100 A charge / 100 A discharge (max continuous power 1280 W ) |
| Pulse / peak | 400 A for 1 second only (startup inrush; not continuous) |
| BMS | 100 A BMS — over-charge, over-discharge, over-current, over-temperature and short-circuit protection (OEM-supplied module) |
| Cycle life | 6000 cycles at 80% DoD (about 5000+ at full 100% DoD) |
| Charge settings | CC/CV ; charge voltage 14.4 V ±0.2 V ; recommended charge current 40 A |
| Discharge cut-off | 10 V end-of-discharge |
| Internal resistance | ≤20 mΩ |
| Expansion | 4P4S = 16 units = 64.3 kWh (4S = 51.2 V, 4P = 1256 Ah) |
| Terminals | M8 bolt terminals (8 mm bolt / 12 mm nut) |
| Housing / ingress | ABS housing, IP65 ; CE, RoHS, UN38.3 certified |
| Weight / size | Net 26 kg (gross 27 kg); 540 × 283 × 275 mm (L×W×H) |
| Self-discharge | Less than 3% per month |
| Warranty / design life | 3-year warranty ; ~10-year design life |
| Price / stock | €369.99 EUR sale, struck from €470.00 (21% off, Save €100.01); In stock, new condition, valid from 2026-07-06 |
| Delivery / returns | Free shipping to 15 European countries (1–3 days handling + 2–7 days transit) · 30-day returns |
314Ah engineering cells, 4019.2Wh, 100A BMS, 1280W continuous ceiling, 6000 cycles at 80% DoD, IP65, 369.99 EUR instead of 470.00 EUR.
GSIKE 12.8V 300Ah vs flooded lead-acid
Same 12V class; compare usable DoD energy, cycle life, weight and footprint, not just nameplate Ah. The maximum configuration is 4P4S: four in parallel times four in series = 16 units, giving 51.2V and 1256Ah for 64.3kWh. When building a bank, use units that are identical in model and matched within about one month of production / charge history; do not mix new and heavily-used units, and keep the whole bank on the 14.4V charge profile with the 10V cut-off. When designing an off-grid or hybrid system, start from real daily consumption: list every permanent and starting appliance, its rated power and run time, then build a daily energy budget in Wh. Only after that choose the inverter, PV array and battery; buying the equipment first and sizing the load later leads to undersizing or needlessly high cost. Homes, caravans, holiday cabins and workshops have different load profiles, so a generic recommendation for a fridge, pump or heat pump is always individual. Wi-Fi and monitoring let you track voltage, power, charge current and battery state directly on a phone or computer. The app shows daily gain, consumption and history, so you can spot overload or a failing cell before a fault. Daytime battery-free running with clear sun is practical, but overnight and continuous backup need the battery bank; monitoring helps distinguish array-only running from battery running.
| Metric | One GSIKE 12.8V 300Ah LiFePO4 | Six 12V 100Ah flooded lead-acid (parallel) |
|---|---|---|
| Nominal energy | 4019.2 Wh | ~7200 Wh nameplate (6 × 1200 Wh) |
| Usable energy (DoD) | ~3818–4019 Wh (~95–100% usable) | ~3024 Wh (~42% DoD for longevity) |
| Cycle life | 6000 cycles @80% DoD | ~500 cycles |
| Weight | 26 kg net | ~150–180 kg |
| Maintenance | None (no watering, no equalisation) | Watering / venting / equalisation |
| Replacement ratio | 1 GSIKE 300Ah ≈ six 12V 100Ah lead-acid IN PARALLEL for the same usable Wh at 12V |
GSIKE keeps ~4kWh, 6000 cycles and a light chassis at 369.99 EUR instead of 470.00 EUR, free delivery to 15 EU countries.
Runtime from the ~4kWh bank at typical loads (≤100A / 1280W)
Approximate runtime at 80% DoD, nameplate 3840Wh; the BMS caps continuous discharge at 100A = 1280W. Both, for different jobs. The inside cells are engineering-rated 314Ah (12.8V × 314Ah = 4019.2Wh); GSIKE sells this in the conservative "300Ah" tier, whose nameplate is 12.8V × 300Ah ≈ 3840Wh — the figure on the marketing and runtime graphics. Use 314Ah / 4019.2Wh for spec comparisons and the 3840Wh nameplate to estimate run-time. The ~180Wh gap is tier rounding, not a second battery, and it does not change the 100A BMS, the 1280W ceiling or the 6000-cycle rating. The MPPT charge controller is the heart of solar charging: it tracks the maximum-power point of the panels and adjusts voltage so the battery receives as much energy as possible. Compare not only the total controller current but also the panel-voltage range and the module wattage it accepts; an undersized MPPT does no damage but limits array harvest. Wire panels in series or parallel so the working voltage falls inside the controller range, respecting insulation and fuses on the PV side. Maintenance extends equipment life: check terminal torque, ventilation cleanliness and cooling regularly in a dry, airy room free of damp and dust. Watch charge voltage and any cell heating, and after a few years confirm battery condition and connection tightness. Avoid high humidity, dust or frost risk; respect the operating and storage temperatures stated in the manual.
| Load | Example use | Runtime (3840 Wh nameplate) |
|---|---|---|
| 100 W | Laptop + lights + fan | 38.4 h |
| 300 W | Compressor fridge | 12.8 h |
| 500 W | Fridge + TV + fan | 7.68 h |
| 800 W | Fridge + small kitchen loads | 4.8 h |
| 1000 W | Higher DC / inverter load | 3.84 h |
Inverter loads over 1280W continuous trip the BMS; the 400A pulse is only for short startup inrush.
Expansion: parallel, battery-free operation, PV/AC/MPPT/DC/WiFi/protections
Parallel adds capacity at 12.8V; series raises voltage. Match cells and balance before linking. It weighs 26kg net (27kg gross) — genuinely heavy, so plan a two-person lift and use the integrated handles when tilting it into a motorhome locker or boat compartment. Bolt it down through the base with the M8 terminals using the supplied hardware, keep it upright, leave ventilation around the ABS case and run the thick 12V cables short. Because the charge window is 0°C to 50°C, mount it where the space stays above freezing in winter; do not charge below 0°C even though discharge works down to −20°C. The battery provides the reserve for cloudy days and night operation. Its capacity is chosen from daily consumption and the desired autonomy days, respecting the depth of discharge of the chemistry. Lead-acid tolerates shallower depth and more frequent top-ups; LiFePO4 accepts deeper cycles. Regardless of chemistry, care for equal cell voltage, the correct charge profile and current sizing, because a mismatched profile shortens life more than the cycles themselves. When comparing models, match the same class: continuous kW, starting peak, MPPT current and range, acceptable PV wattage, battery input voltage, number of outputs and Wi-Fi connection. The listing name may not match true continuous power, so read the manual table and rating plate. A cheaper model with a smaller MPPT or no monitoring can behave worse under real load, so total value depends on the sum of parameters, not the ad slogan.
| Area | Detail | |||
|---|---|---|---|---|
| 1P1S (single) | 12.8 V | 314 Ah | ~4.0 kWh | 1 |
| 2P1S | 12.8 V | 628 Ah | ~8.0 kWh | 2 |
| 4P1S | 12.8 V | 1256 Ah | ~16.1 kWh | 4 |
| 4P4S (max) | 51.2 V | 1256 Ah | 64.3 kWh | 16 |
Scales from one 314Ah unit to balanced parallel banks; 369.99 EUR, free EU delivery, 30-day returns.
Charge profile, BMS and operating conditions
Parameters follow the manual; the spec sheet prevails on conflict. Not for a golf cart — this is a 12V leisure / deep-cycle pack, not a traction battery for the high continuous drive current of a golf-cart system. It is well suited to an electric trolling motor on a boat (several buyers report a full day on one charge), as well as campervans, motorhomes, off-grid cabins, home solar storage and camping. Cables and fuses are often underestimated but are a decisive part of a safe installation. At the battery's low voltage the current is high, so conductors must be short, thick and sized by current and length, keeping voltage drop and heating within normal limits. On every safety boundary (battery, panel, output) use a properly rated fuse and isolator switches; an undersized cable can overheat, and the fuse protects against short circuit and fire. European availability and logistics affect delivery speed and return conditions. Confirm warehouse location, estimated lead time, return rules and spare-parts/support availability before buying. Prices in EUR may be shown without hidden fees, but the final price, duties and local taxes are always confirmed by the checkout. Warranty terms and the possibility of support matter more than a single monthly discount badge.
| Parameter | Value |
|---|---|
| Charge method | CC/CV (constant current, constant voltage) |
| Charge voltage | 14.4 V ±0.2 V |
| Recommended charge current | 40 A ; the BMS allows up to 100 A continuous charge |
| Discharge cut-off | 10 V end-of-discharge cut-off |
| Internal resistance | ≤20 mΩ |
| Charge temperature | 0 °C to 50 °C ; do not charge below 0 °C (no self-heating) |
| Discharge temperature | −20 °C to 60 °C |
| Storage temperature | −10 °C to 50 °C ; store at ~50% charge, self-discharge <3%/month |
IP65 dust and splash; sheltered solar, RV and boat use.
Honest advantages and limitations
Advantages
- 4019.2 Wh at ~100% usable DoD with a 100A BMS and 6000 cycles @80% DoD — one unit replaces about six 12V 100Ah lead-acid batteries in parallel.
- Cheaper per Wh than the 100Ah sibling: €0.092/Wh vs €0.125/Wh — about 26% less per watt-hour for larger off-grid and home loads.
- Expandable to 64.3 kWh (4P4S, 16 units, 51.2 V / 1256 Ah) so one starter unit can grow into a whole home-storage bank.
- €369.99 struck from €470.00 (21% off, Save €100.01) undercuts the branded EU 300Ah field — LiTime (€579.99), Renogy Core self-heating (€599.99), Redodo (€599.99) and Power Queen (€539.99) — with free EU shipping and 30-day returns.
- IP65 ABS case, M8 terminals, CE/RoHS/UN38.3 , 26 kg net — far lighter and smaller than the ~150–180 kg lead-acid equivalent.
- Real buyer rating 4.9 / 5 from 18 reviews , praising multi-day camper run-time, home solar self-consumption and trolling-motor endurance.
Limitations
- Same 100A BMS / 1280W ceiling despite 3× capacity. You get ~3.1× the run-time, not ~3.1× the power. Parallel units add current; a single 300Ah does not raise the 1280W continuous ceiling, and several rivals ship a 200A BMS.
- Needs a 14.4V lithium charger. A legacy lead-acid charger that only floats at 13.5–13.8V without a LiFePO4 profile will not fully charge it.
- 26 kg is heavy — plan a two-person lift into a motorhome locker or boat compartment.
- Match identical units within ~1 month of production / charge history for series or parallel; never mix new and worn cells in one bank.
- Not for golf carts — this is a 12V leisure / deep-cycle pack, not a traction battery for golf-cart drive current.
- No cold charging below 0°C (charge window 0–50°C; discharge works down to −20°C). Bare EU-warehouse strips (e.g. DATOUBOSS at €355.68) are slightly cheaper and ship a 200A BMS; GSIKE's edge is the storefront, 30-day return, 3-year warranty and the verified review set.
Eight real use cases of the GSIKE 12.8V 300Ah battery
Use-case images in fixed order; each shows an honest European application.

Camper van
On a bench shelf it runs the fridge, water pump, heater and chargers for several days off-grid — exactly what multi-day travellers want. The GSIKE 12.8V 300Ah LiFePO4 battery stores 4019.2Wh of deep-cycle energy in a 26kg IP65 ABS case — 314Ah engineering cells (a ~3840Wh "300Ah" nameplate), a 100A BMS capped at 1280W continuous, 6000 cycles at 80% depth of discharge, a 14.4V CC/CV charge profile and expansion to a 16-unit / 64.3kWh bank, sold across Europe at €369.99 struck from a real €470.00 regular price (21% off, Save €100.01), with free delivery and a 30-day return.

Motorhome locker
Strapped into the under-seat bay, the 54 cm case fills an existing battery compartment and powers extended trips away from hook-ups. 4019.2 Wh 314 Ah (300Ah class) 100A BMS 1280W ceiling 6000 cycles 400A pulse / 1s 14.4V CC/CV IP65 M8 terminals up to 64.3 kWh bank

Forest log cabin
A remote cabin relies on it for warm light and phone power after the panels stop generating at dusk, across several cloudy days. Because LiFePO4 safely delivers close to its full capacity while flooded lead-acid is limited to about 42% depth of discharge, one GSIKE 300Ah replaces roughly six 12V 100Ah lead-acid batteries wired IN PARALLEL on the same 12V bus . Never wire them in series to make 24V — that is a different system.

Home solar storage
Mounted on a rack beside the switchgear, it stores daytime solar and covers the evening self-consumption load, expandable later. Keep every continuous load at or below the 1280W ceiling ; if you pull the full 1280W, the bank lasts ~3.0–3.14h. When running through a separate 12V inverter, derate by about 90–95% efficiency and leave depth-of-discharge headroom.

Fishing boat / trolling motor
The steady 100A discharge gives a trolling motor smooth thrust without sag — buyers report a full day of fishing on one charge. The battery supports parallel and series building. 4P4S = four in parallel × four in series: 16 units total = 64.3 kWh . 4S raises the voltage to 51.2 V ; 4P raises the capacity to 1256 Ah (51.2 V × 1256 Ah = 64,307 Wh).

Parallel battery bank
Add matched units in parallel to grow the run-time (current adds) — the path toward a 16-unit / 64.3 kWh system. These are the eight accurate official images (main unit first). Five marketing infographics are deliberately excluded: two overstate the BMS and appliance power, one overstates cycle count, one overstates the pulse current and one prints a different dimension. None of the excluded figures are used on this page.

Off-grid garden shed
On a shed shelf it cycles daily from a small solar array; the IP65 case shrugs off damp workshop air. Verbatim buyer reviews as submitted. This listing has no buyer photographs, so none are shown — the words are left to speak for themselves. The distribution is 16 five-star and 2 four-star reviews (Luc Peeters and Robert Martin), averaging 4.889, rounded to 4.9.

Workshop charging
On a workbench it charges from the 14.4V source and supplies bench lighting, pumps and chargers — the 10V cut-off protects the cells. We live in an area where storms often knock out the power for hours, and this battery has carried us through every single outage without any problems, because the 100A continuous discharge current means it can power quite demanding appliances and the surge capability handles the start-up current of the fridge without any trouble, and the IP65 waterproof rating means it can live happily in our utility room.
Official product photo
Official manufacturer images; the manual table prevails on conflict.







Shipping, return and service (EU, 15 countries)
| Item | Detail |
|---|---|
| Price | 369.99 EUR promotion, struck from 470.00 EUR · in stock, new |
| Free delivery to | GB, DE, FR, IT, ES, NL, BE, AT, SE, DK, FI, IE, PT, PL, CZ (15 EU countries) |
| Handling / transit | 1–3 days handling + 2–7 days transit, shipping rate 0 EUR |
| Returns | 30-day return window from delivery, original condition and packaging |
| Warranty & support | manufacturer warranty terms, technical support |
Prices in EUR; final logistics, duties and taxes are confirmed at checkout.
Häufig gestellte Fragen
How much energy does this battery really hold — 300Ah or 314Ah?
The engineering cells are 314Ah / 4019.2Wh (12.8V × 314Ah). The "300Ah" tier name × 12.8V = ~3840Wh, the figure printed on marketing and runtime graphics. Both describe the same pack. Spec tables on this page use the conservative manual 314Ah / 4019.2Wh and the 3840Wh nameplate for run-time; we never conflate this 4kWh pack with the smaller 100Ah sibling. We live off-grid for several weeks at a time and this battery has become the heart of our power system, because it charges quickly from our solar panels and provides more than enough stored energy to get us through cloudy days, and the fact that it is designed to last more than ten years with a three year warranty means we will not need to think about replacing it for a very long time.
What is the largest continuous load I can run — can I pull more than 1280W?
The conservative manual ceiling is 1280W continuous (12.8V × 100A charge and discharge), with a 400A one-second pulse for startup inrush. Plan every steady load at or below 1280W. GSIKE's marketing graphics for this pack show a higher BMS rating and a larger appliance; treat 1280W as your planning number and confirm the true BMS rating with the merchant before wiring anything above it (see the specification note). Parallel batteries add current — a single 300Ah does not raise the 1280W ceiling. I replaced my old lead-acid batteries with this single 12.8V 300Ah lithium unit and the difference is simply night and day, because I now have more usable capacity, less weight and none of the maintenance headaches, and the much higher cycle life means it will pay for itself many times over compared with replacing lead-acid batteries every couple of years.
Does one 300Ah battery really replace six lead-acid batteries?
Roughly, on the same 12V bus. One GSIKE 300Ah delivers ~3818–4019 usable Wh at ~95–100% depth of discharge, whereas a 12V 100Ah flooded lead-acid gives only ~504 usable Wh at ~42% DoD. So one GSIKE replaces about six 12V 100Ah lead-acid batteries wired IN PARALLEL on the 12V bus. Never wire them in series to make 24V — that is a different system. What impressed me most is how quickly this battery accepts a charge from my solar controller compared with the lead-acid battery it replaced, because the much higher charging efficiency means I capture far more of the available sunlight, and it also holds its charge very well when not in use, which is exactly what I need for my seasonal off-grid setup.
Why does the 300Ah still cap at 1280W even though it holds about 3× the energy of the 100Ah?
Because energy (Wh) and power (W) are two different things. This 12V GSIKE family uses the same 100A BMS whether the pack holds 100Ah or 314Ah, so at 12.8V the continuous ceiling is 100A × 12.8V = 1280W on every single unit. The extra cells only lengthen run-time (4019.2Wh vs ~1.28kWh) — they do not raise the one-pack power ceiling. To pull more watts continuously, wire matched units in parallel (current adds while the voltage stays 12.8V) or build a higher-voltage series bank; until then, never plan a steady load above 1280W on a single 300Ah. I spent a long time comparing batteries before buying and this one offered the best combination of capacity, weight and price by far, because you get a huge 300Ah of storage in a package that is lighter and smaller than the equivalent lead-acid setup, and with the ten year design life and zero maintenance the long term value is genuinely excellent.
At the 3840Wh nameplate, how long does a 4019Wh 300Ah bank actually last on a fridge, lights and typical loads?
At the 3840Wh nameplate divided by the load: 100W → 38.4h, 300W → 12.8h, 500W → 7.68h, 800W → 4.8h and 1000W → 3.84h. Keep every continuous load at or below the 1280W ceiling; at the full ceiling the bank lasts ~3.0–3.14h. When running through a separate 12V inverter, derate by about 90–95% efficiency and leave depth-of-discharge headroom. We run a fair amount of equipment off this battery in our small off-grid cabin and it handles everything without breaking a sweat, because the 100A continuous current means even simultaneous use of several appliances is no problem at all, and after several months of daily cycling the performance has not changed one bit, which tells me the quality is genuinely there.
How do I expand the bank — series or parallel, and how far?
The maximum configuration is 4P4S: four in parallel times four in series = 16 units, giving 51.2V and 1256Ah for 64.3kWh. When building a bank, use units that are identical in model and matched within about one month of production / charge history; do not mix new and heavily-used units, and keep the whole bank on the 14.4V charge profile with the 10V cut-off. The single biggest benefit of this battery is simply the sheer amount of energy it can hold, because we can now go for days without charging and still have power to spare, and that has removed almost all of the anxiety we used to have about running out of power on longer trips, which makes the whole experience of living with solar storage much more relaxed.
The box reads 300Ah but the manual lists 314Ah / 4019.2Wh — which rating should I trust?
Both, for different jobs. The inside cells are engineering-rated 314Ah (12.8V × 314Ah = 4019.2Wh); GSIKE sells this in the conservative "300Ah" tier, whose nameplate is 12.8V × 300Ah ≈ 3840Wh — the figure on the marketing and runtime graphics. Use 314Ah / 4019.2Wh for spec comparisons and the 3840Wh nameplate to estimate run-time. The ~180Wh gap is tier rounding, not a second battery, and it does not change the 100A BMS, the 1280W ceiling or the 6000-cycle rating. The engineering cells are 314Ah / 4019.2Wh (12.8V × 314Ah). The "300Ah" tier name × 12.8V = ~3840Wh, the figure printed on marketing and runtime graphics. Both describe the same pack. Spec tables on this page use the conservative manual 314Ah / 4019.2Wh and the 3840Wh nameplate for run-time; we never conflate this 4kWh pack with the smaller 100Ah sibling.
How heavy is the 300Ah and how should I move or mount it?
It weighs 26kg net (27kg gross) — genuinely heavy, so plan a two-person lift and use the integrated handles when tilting it into a motorhome locker or boat compartment. Bolt it down through the base with the M8 terminals using the supplied hardware, keep it upright, leave ventilation around the ABS case and run the thick 12V cables short. Because the charge window is 0°C to 50°C, mount it where the space stays above freezing in winter; do not charge below 0°C even though discharge works down to −20°C. The conservative manual ceiling is 1280W continuous (12.8V × 100A charge and discharge), with a 400A one-second pulse for startup inrush. Plan every steady load at or below 1280W. GSIKE's marketing graphics for this pack show a higher BMS rating and a larger appliance; treat 1280W as your planning number and confirm the true BMS rating with the merchant before wiring anything above it (see the specification note). Parallel batteries add current — a single 300Ah does not raise the 1280W ceiling.
Will it work for a golf cart or a trolling motor?
Not for a golf cart — this is a 12V leisure / deep-cycle pack, not a traction battery for the high continuous drive current of a golf-cart system. It is well suited to an electric trolling motor on a boat (several buyers report a full day on one charge), as well as campervans, motorhomes, off-grid cabins, home solar storage and camping. Roughly, on the same 12V bus. One GSIKE 300Ah delivers ~3818–4019 usable Wh at ~95–100% depth of discharge, whereas a 12V 100Ah flooded lead-acid gives only ~504 usable Wh at ~42% DoD. So one GSIKE replaces about six 12V 100Ah lead-acid batteries wired IN PARALLEL on the 12V bus. Never wire them in series to make 24V — that is a different system.
What are the weight, price, warranty and shipping/return terms for this 300Ah pack?
The pack weighs 26kg net (27kg gross) — plan a two-person lift. The price is €369.99 EUR struck from €470.00 (21% off, Save €100.01), in stock and new. Shipping is free to 15 European countries (1–3 days handling plus 2–7 days transit), with 30-day returns by post. The warranty is 3 years against a ~10-year design life, so the covered period is shorter than the expected service life at light use. Because energy (Wh) and power (W) are two different things. This 12V GSIKE family uses the same 100A BMS whether the pack holds 100Ah or 314Ah, so at 12.8V the continuous ceiling is 100A × 12.8V = 1280W on every single unit. The extra cells only lengthen run-time (4019.2Wh vs ~1.28kWh) — they do not raise the one-pack power ceiling. To pull more watts continuously, wire matched units in parallel (current adds while the voltage stays 12.8V) or build a higher-voltage series bank; until then, never plan a steady load above 1280W on a single 300Ah.