51.2V 100Ah 5.12kWh Wall Mount Built-in BMS

GSIKE FixWall 5.0 — 51.2V 100Ah (5.12kWh) Wall LiFePO4 Battery With Built-in BMS for Backup and Self-Consumption in Czechia Homes

A 51.2V 100Ah wall-mounted LFP pack holding 5.12kWh for English-speaking residents and expats in Prague, Brno and other Czech cities who store daytime rooftop PV for the evening load and keep an essential-circuit reserve during an outage; listed at €849.99 against a struck reference price of €1,250.00, with a three-year warranty.

Product Overview

Designed for a Czech city apartment, family house, utility room or countryside cottage, this slim 48V-class pack bolts to a steel bracket next to the hybrid inverter. It lives entirely on the DC bus and performs no AC conversion inside its enclosure. Its 5.12kWh store feeds evening household draws from the rooftop array and keeps key consumers alive through a brief mains break.

GSIKE FixWall 5.0 51.2V 100Ah wall-mounted LiFePO4 pack with round LCD and ring-lug terminals

On the EU storefront the price reads €849.99, struck down from €1,250.00; one variant, currently in stock. Free delivery covers the 15 listed EU markets, Czechia included: order handling 1–3 days, onward transit 2–7 days, a 30-day return window and a three-year warranty. Import duties and taxes are non-refundable. Storefront entry: GSIKE 51.2V 100Ah LiFePO4 battery on gesike.com.

51.2VNominal 48V-class bus
100AhRated cell capacity
5.12kWhStored energy
6,000Cycles at 80% DoD

Battery and Electrical Specifications

Every figure below traces to the verified 100Ah FixWall 5.0 record. Sixteen 3.2V LFP cells in series run through the built-in smart BMS; the enclosure adds no mains outlets, no phone app and no warming element.

Specification Detail
Chemistry and assembly 3.2V LiFePO4 cells in a 16S1P arrangement, sixteen in series with one parallel row
Nominal voltage 51.2V, the 48V-class bus used for residential storage
Capacity and energy 100Ah at 5120Wh, equal to a 5.12kWh store
Continuous current 50A charge and discharge, or 2560W; ordinary household loads should be planned near a 2.56kW ceiling
Short-time current 100A peaks at 5120W briefly; this peak regime is not sustained
Working voltage 43.2V to 58.4V, with discharge cut-off close to 43.2V
Charge voltage 58.4V bulk and absorption, the usual 16S LFP CC/CV profile
Built-in smart BMS Guards against over-charge, over-discharge, over-current, short-circuit, high and low temperature, and surge events
Communication ports RS232, a dual RS485 link at 9600 bps, and CAN-BUS at 500 kbps for closed-loop pairing with a compatible 48V hybrid inverter
Cycle life 6000 cycles at 80% DoD and 25°C, with a design life around ten years
AC output None on this unit; it stays a battery-only DC pack matched to a separate 48V hybrid inverter
Monitoring Round LCD plus power switch; WiFi, Bluetooth and phone application are absent
Capacity infographic for the 100Ah wall pack: 5120Wh, 5.12kWh stored energy rating Smart BMS infographic listing over-charge, over-discharge, over-current, short-circuit and temperature guards

Expansion, Mounting and Housing

Additional packs join in parallel only; the unit hangs from a steel bracket behind an IP54 case meant for an indoor or sheltered dry room. Given Czechia's cold continental winters, keep the pack in a heated or frost-free interior rather than an unheated garage or exposed outer wall where damp and freezing can set in.

Specification Detail
Expansion topology Parallel strings only, up to 16 units on the 51.2V bus for an 81.92kWh bank; series stacking is excluded
Mixing rule Brands and capacities are never combined inside one parallel bank
Mounting hardware Steel wall bracket fastened with expansion bolts; bracket roughly 409.5 × 322 mm
Terminals Copper-alloy ring-lug terminals for fixed cable connections
Housing and ingress ABS and metal enclosure, IP54 dust-tight and splash-proof, for indoor or sheltered dry-room placement
Certifications CE, RoHS, UN38.3
Operating temperature −10°C up to 50°C
Storage temperature 0°C to 35°C, humidity under 95% RH, altitude below 2000 m
Low-temperature charging No self-heating fitted; charging must not occur below 0°C
Net weight 44kg, within a 44 ±2 tolerance
Dimensions 640 high × 428 wide × 160 deep mm
Parallel expansion infographic showing up to sixteen wall packs on a single 51.2V bus Temperature envelope infographic for the wall pack with operating and storage ranges

Czech Home Energy Context

Midday rooftop PV held in the pack is released into the evening household draw, shifting use away from peak billing and keeping essential circuits ready during a local cut. How long the reserve lasts hinges on the load drawn, inverter efficiency and depth of discharge. The battery drives a compatible single-phase 230V 48V hybrid inverter; that separate device decides AC output, phase count and backup switching.

Context Point Detail
230V pairing The pack feeds a compatible single-phase 230V 48V hybrid inverter, which in turn supplies mains AC to the dwelling's appliances
Rooftop self-consumption Daylight PV held on board covers evening cooking, lighting and appliance draws instead of being exported at a lower export rate
Outage reserve Lights, the refrigerator and network gear among other essential circuits stay on the battery through a short break until the grid returns
Placement fit The 160mm-deep enclosure suits a Prague or Brno city flat, a family-house cupboard, a basement, a garage or a countryside chalupa beside the existing services
Winter placement Continental winters demand a frost-free, ventilated indoor spot; an unheated outbuilding risks holding the cells under the charging threshold
Wall pack paired with a residential PV system for evening solar self-consumption in a Czech home Wall-mounted battery holding an essential-circuit reserve during an evening grid interruption

In the Box

Item Included
FixWall 5.0 51.2V 100Ah battery pack Yes
Wall mounting bracket and expansion bolts Included
Power cable and communication cable Included
User manual Included
Hybrid inverter, solar panels or mounting rails Supplied separately to match the chosen installation

Pros & Cons

Objective Strengths

  • Handy reserve: the 5.12kWh 48V LFP store covers evening self-consumption and essential-load backup around a Czech home.
  • Talking BMS: RS232, twin RS485 and CAN-BUS exchange charge and discharge limits with the paired hybrid inverter.
  • Long service span: 6000 cycles at 80% DoD and 25°C, a roughly ten-year design life, wrapped in a three-year warranty.
  • Room to grow: sixteen parallel packs can later widen the bank to 81.92kWh as storage demand climbs.
  • Marked build: IP54 enclosure with CE, RoHS and UN38.3 certification for a fixed indoor install.
  • Shallow wall case: bracket fixing and ring-lug terminals fit a compact garage, storeroom or utility room.

Objective Weaknesses

  • DC-only pack: no mains outlet lives inside; appliances need a separate 48V hybrid inverter.
  • Steady-state limit: continuous draw is capped at 50A, 2560W; the 100A / 5120W figure is a peak that cannot be held.
  • No companion app: state of charge shows on the round LCD alone; WiFi, Bluetooth and phone control are omitted.
  • Parallel-only wiring: higher-voltage series strings are unavailable, and another brand or Ah rating cannot enter the bank.
  • Cold-weather limit: no cell warming resistor exists, and charging at sub-zero temperatures is not allowed.
  • Lifted on two people: at 44kg the pack needs two-person lifting and a wall strong enough for the full load.

Real-World Scenarios

Fixed roles match this 48V pack to an inverter in a home, services room or light-backup setting; it is not carried around as a portable source.

Bracket-mounted pack on a technical-room wall beside the home inverter and consumer unit

Technical-Room Wall Position

On a dry inner wall, the pack sits close to the hybrid inverter for a short DC run, with space left around it for service.

Pack placed in a heated services room next to household services and the electrical distribution board

Heated Services Room

Next to the home heating and electrical circuits, the bank keeps its reserve ready to ride through a supply interruption.

CAN or RS485 communication cable linking the pack to a compatible hybrid inverter

Inverter Communication Pairing

Across the CAN or RS485 wire, the BMS hands over its charge voltage and discharge cut-off limits to the paired inverter.

Slim wall pack fitted into a spare corner of a narrow city apartment in Prague or Brno

City Apartment Mount

The shallow 160mm case fills a spare indoor corner in a multi-storey or compact central-city dwelling.

Pack storing solar reserve for evening and overnight loads in a countryside cottage or family house

Chalupa and Country House Reserve

A countryside cottage or family house holds daytime PV here for evening and overnight use, where the mains can be less dependable.

Two identical wall packs joined in parallel to increase total stored energy

Parallel Second Pack

If one 5.12kWh unit turns out too small, a matching second pack joins the same bus to enlarge the store.

Sheltered indoor installation of the wall pack with fixed cabling and ventilation clearance

Sheltered Fixed Install

The enclosure stays indoors or under cover, leaving clearance around the case for airflow and later maintenance.

Frequently Asked Questions

How many volts, amp-hours and kilowatt-hours does the FixWall 5.0 specify?

On the 51.2V nominal 48V-class bus it holds 100Ah, equivalent to 5120Wh or 5.12kWh, with 3.2V LiFePO4 cells arranged in a 16S1P block.

Can household appliances be powered straight from this wall pack?

Not by itself. No mains outlet sits inside the enclosure; the unit stays on the DC side and must go through a separate 230V 48V hybrid inverter before any appliance can run.

Which inverter protocols does the pack speak in a Czech home setup?

Signals travel on RS232, two RS485 ports and CAN-BUS. Confirm before ordering that your inverter uses the matching Pylontech-compatible protocol and the 58.4V charge profile.

How many identical packs may share one 51.2V parallel bus?

Sixteen matching units is the parallel ceiling, reaching an 81.92kWh bank on the 51.2V bus. Series wiring is not offered, and packs from another brand or Ah rating cannot share that bank.

What sustained and peak current figures does the 100Ah pack allow?

Steady charge and discharge run at 50A, or 2560W. The 100A / 5120W level is only a brief peak ceiling and cannot be held as a continuous draw.

What cycle lifetime and warranty cover this wall pack?

Cells are rated to 6000 cycles at 80% depth of discharge and 25°C, with an approximate ten-year design span, and the pack carries a three-year warranty.

Can this LFP unit replace an old 48V lead-acid bank in a Czech PV retrofit?

Being 48V class, it can take over from an ageing lead-acid solar bank once the inverter adopts the 58.4V bulk/absorption voltage and recognises the correct BMS protocol.

How is the pack mounted indoors, and what do it weigh and measure?

A steel bracket fixed with expansion bolts carries it on the wall. Net weight 44kg; case 640 H × 428 W × 160 D mm; round LCD, switch and copper-alloy ring-lug terminals, IP54 for indoor or sheltered locations.

Which conditions does the wall pack's smart BMS protect against?

Its controller watches for over-charge, over-discharge, over-current, short-circuit, high and low temperature, and surge voltage, while keeping the internal cells balanced.

Which ambient and storage limits apply, and may charging happen below freezing?

Ambient use spans −10°C to 50°C; storage sits between 0°C and 35°C. No warming resistor is fitted, and sub-zero cell charging is forbidden.

Related GSIKE Guides for Czechia

Gsike 51.2V 100Ah Wall Battery for Self-Consumption and Backup Under Czech Household Electricity Conditions

Walk through self-consumption rates, the evening household draw and reserve assumptions for a 5kWh wall pack under Czech household conditions.

Best 5kWh Wall LiFePO4 Batteries for 230V Homes: Gsike 100Ah Compared With Certified Rivals in Czechia

How the FixWall 5.0 lines up with established CE-certified 5kWh wall options on format, communication lines and warranty positioning.

Sizing a 5.12kWh Gsike Wall Battery for Evening Backup and Self-Consumption During Outages

Match evening household kWh and essential outage loads against the 5.12kWh reserve, and settle on storage size for a typical Czech home.

Installing a Gsike 100Ah Wall Battery With a 230V Hybrid Inverter: Wall-Mount and CE/IEC Guide

Go over wall-mount checks, comms wiring, charge-profile matching and CE/IEC points for a Czech retrofit installation.

51.2V 100Ah LiFePO4 battery, 48V 100Ah home battery, 5kWh wall mounted battery, 230V hybrid inverter battery, 48V 100Ah 5.12kWh LiFePO4 wall battery, GSIKE FixWall 5.0, 5kWh solar battery for a Czech home, low-voltage 48V LFP battery for PV storage, wall-mounted LiFePO4 battery with BMS and CAN, 48V 100Ah battery for a 230V solar hybrid inverter, evening self-consumption wall battery for Czechia, 5kWh backup pack for apartment, family house and chalupa