Home GSIKE FixWall 5.0: 100Ah 5.12kWh Wall Battery, Romania
GSIKE FixWall 51.2V 100Ah LiFePO4 Battery 5.12kWh
GSIKE FixWall 51.2V 100Ah LiFePO4 Battery 5.12kWh

GSIKE FixWall 5.0: 100Ah 5.12kWh Wall Battery, Romania

Regular price €1.250,00 Sale price €849,99
32% OFF

Estimate delivery times: 2-7 Business days (European Union, United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

GSIKE FixWall 51.2V 100Ah LiFePO4 Battery 5.12kWh

GSIKE FixWall 5.0: 100Ah 5.12kWh Wall Battery, Romania

€849,99
Description
51.2V 100Ah 5.12kWh Wall Mount Built-in BMS

GSIKE FixWall 5.0 — 51.2V 100Ah (5.12kWh) Wall LiFePO4 Battery With Built-in BMS for Backup Power and Solar Self-Consumption in Romanian Homes

A 51.2V 100Ah wall-mounted LFP pack holding 5.12kWh, built for English-speaking households in Romania that store daytime rooftop PV for the evening load and keep an essential-circuit reserve during a grid interruption; listed at €849.99 against a struck reference of €1,250.00, with a three-year warranty.

Product Overview

This slim 48V-class low-voltage storage unit hangs on a steel bracket beside the hybrid inverter in a Bucharest or Cluj-Napoca apartment, a family house, or a countryside village home. It works only on the DC bus and does not convert stored energy to alternating current within its own case. The 5.12kWh reserve supports evening self-consumption from the home PV array and supplies essential consumers for a short period while the network is down.

GSIKE FixWall 5.0 51.2V 100Ah wall-mounted LiFePO4 pack with round LCD and ring-lug terminals

The offer lists €849.99 against a struck €1,250.00 reference; one variant, currently in stock. Complimentary carriage and the 30-day return tied to this listing apply only to the 15 EU destinations listed in the terms, after 1–3 days handling and 2–7 days transit; a three-year warranty applies, and any import duties or taxes are non-refundable. Romania is excluded from that destination set, so a buyer with a Romanian address should verify current delivery options and any import steps with the seller before ordering; complimentary carriage and the return window cover only those listed EU countries. Listing link: Open the GSIKE 51.2V 100Ah battery listing on gesike.com.

51.2VNominal 48V-class bus
100AhRated cell capacity
5.12kWhStored energy
6,000Cycles at 80% DoD

Battery and Electrical Specifications

Each electrical figure below draws on the verified 100Ah FixWall 5.0 record. The 3.2V LFP cells sit in a 16S1P layout watched by the built-in smart BMS. This case has no AC outlets, no phone app and no warming element.

Specification Detail
Chemistry and assembly LiFePO4 3.2V cells, 16S1P (16 in series, 1 parallel)
Nominal voltage 51.2V (48V-class residential storage bus)
Capacity and energy 100Ah / 5120Wh = 5.12kWh
Continuous current 50A charge/discharge, equal to 2560W; plan ordinary household loads around roughly 2.56kW
Short-time current 100A = 5120W, a short-time ceiling only; this regime is not held continuously
Working voltage 43.2V – 58.4V; discharge cut-off near 43.2V
Charge voltage 58.4V bulk/absorption, standard 16S LFP CC/CV profile
Built-in smart BMS Protection against over-charge, over-discharge, over-current, short-circuit, high and low temperature, and surge voltage
Communication ports RS232, dual RS485 at 9600 bps, CAN-BUS at 500 kbps for closed-loop pairing with a compatible 48V hybrid inverter
Cycle life 6000 cycles at 80% DoD @25°C; design life roughly ten years
AC output None; battery-only DC pack, paired with a separate 48V hybrid inverter
Monitoring Round LCD and power switch; no WiFi, Bluetooth or phone application
Capacity infographic for the 100Ah wall pack: 5120Wh, 5.12kWh stored energy rating Smart BMS infographic listing over-charge, over-discharge, over-current, short-circuit and temperature guards

Expansion, Mounting and Housing

The bank expands in parallel only, hangs from a steel wall bracket, and sits inside an IP54 case intended for an indoor or sheltered dry room in a Romanian home, where ventilation keeps the enclosure clear of condensation through the continental winter.

Specification Detail
Expansion topology Parallel only, up to 16 units on the 51.2V bus for an 81.92kWh bank (51.2V × 1600Ah); series stacking is not supported
Mixing rule Do not combine brands or capacities within the same parallel bank
Mounting hardware Steel wall bracket with expansion bolts; bracket about 409.5 × 322 mm
Terminals Copper-alloy ring-lug terminals for fixed cabling
Housing and ingress ABS/metal case, IP54 dust-tight and splash-proof; indoor or sheltered dry-room use
Certifications CE, RoHS, UN38.3
Operating temperature −10°C to 50°C
Storage temperature 0°C to 35°C; humidity below 95% RH; altitude under 2000 m
Low-temperature charging No self-heating function; do not charge below 0°C
Net weight 44kg (44 ±2)
Dimensions 640 H × 428 W × 160 D mm
Parallel expansion infographic showing up to sixteen wall packs on a single 51.2V bus Temperature envelope infographic for the wall pack with operating and storage ranges

Home Energy Context in Romania

A 5.12kWh pack moves midday rooftop PV generation into the evening household load, supports time-shifted use against Romanian electricity bills, and holds a reserve for essential circuits during a local interruption. How long the reserve lasts follows the connected load, inverter efficiency and discharge depth. The pack feeds a matched single-phase 230V 48V hybrid inverter; AC output, phase count and backup switching are set by that separate device.

Context Point Detail
230V pairing The pack supplies a compatible single-phase 230V 48V hybrid inverter; that inverter delivers AC to household appliances in the dwelling
Rooftop self-consumption Stored daytime PV covers evening cooking, lighting and appliance loads rather than exporting excess generation at a lower export rate
Outage reserve Essential circuits ride the battery through a short interruption while the system waits for the grid to be restored
Placement fit The 160mm-deep case suits a narrow city flat, a family house, a utility cupboard or a village-house services room
Cold-winter placement Under the continental climate, the pack belongs in a ventilated, frost-free indoor or sheltered position rather than an unheated exposed space
Wall pack paired with a residential PV system for evening solar self-consumption in a Romanian home Wall-mounted battery holding an essential-circuit reserve during an evening grid interruption

In the Box

Item Included
FixWall 5.0 51.2V 100Ah battery pack Yes
Wall mounting bracket and expansion bolts Included
Power cable and communication cable Included
User manual Included
Hybrid inverter, solar panels or mounting rails Not included; chosen separately to match the installation

Pros & Cons

Objective Strengths

  • Useful reserve: the 5.12kWh 48V LFP pack covers evening self-consumption and essential-load backup in a Romanian home.
  • Communicating BMS: RS232, dual RS485 and CAN-BUS share charge and discharge limits with the matched hybrid inverter.
  • Long cycle life: 6000 cycles at 80% DoD @25°C, a near-ten-year design life, and a three-year warranty.
  • Expandable bank: up to sixteen parallel packs reach 81.92kWh as storage demand grows.
  • Certified build: IP54 case carrying CE, RoHS and UN38.3 marks for fixed indoor installation.
  • Slim wall format: bracket mounting and ring-lug terminals suit a compact garage, cupboard or services room.

Objective Weaknesses

  • DC node only: the case delivers no AC, so household appliances run through a separate 48V hybrid inverter.
  • Continuous draw: 50A maps to 2560W continuously, while 100A / 5120W is a brief peak rather than a held level.
  • LCD-only status: state of charge reads on the round LCD only; WiFi, Bluetooth and phone control are absent.
  • Parallel-only expansion: higher-voltage series strings are unavailable, and packs of another brand or rating should not enter the same bank.
  • No warming element: the pack lacks a low-temperature heater, and charging when the cells sit under 0°C must be avoided.
  • Wall-mount weight: the 44kg unit needs two people to lift it and a wall strong enough to carry the load.

Real-World Scenarios

Usual fixed-storage roles pair this 48V pack with an inverter in a home, services or light-backup setting; it is not intended as a portable source.

Technical-Room Wall Position

Technical-Room Wall Position

Mounted on a dry interior wall, the pack is positioned near the hybrid inverter so the DC wiring stays short and easy to service.

Heated Services Room

Heated Services Room

Set beside the home's heating and electrical services, the bank holds its reserve ready to ride through an interruption.

Inverter Communication Pairing

Inverter Communication Pairing

Linked over CAN or RS485, the BMS aligns charge voltage and discharge cut-off with the inverter's set expectations.

Compact City Apartment Mount

Compact City Apartment Mount

The shallow 160mm case fits a spare indoor corner in a Bucharest or Cluj-Napoca flat with limited wall space.

Village Home and Country House

Village Home and Country House

A family house or countryside village home uses the pack to hold daytime PV for evening cooking, lighting and appliance loads.

Weekend House Reserve

Weekend House Reserve

A weekend dwelling outside the city keeps an essential-circuit reserve for lights, fridge and network gear during a short cut.

Sheltered Fixed Install

Sheltered Fixed Install

Placement stays indoors or under cover, leaving clearance around the case for airflow and service access.

Frequently Asked Questions

On what voltage, Ah capacity and energy does the 100Ah pack run?

On the 48V-class rail the pack sits at 51.2V nominal, a 100Ah rating holding 5120Wh, equal to 5.12kWh, built from 3.2V LiFePO4 cells in a 16S1P layout.

Can the wall pack drive household appliances by itself?

No. The case has no AC socket; it is a DC-only unit that must first link to a separate 230V 48V hybrid inverter before any appliance can run.

Which hybrid inverters can the pack pair with in a Romanian setup?

State data travels over RS232, a dual RS485 port and CAN-BUS. Before buying, check that the inverter chosen speaks the matching Pylontech-compatible protocol and accepts the 58.4V charge profile.

How many packs may sit on one 51.2V parallel bus?

Sixteen packs maximum join a single 51.2V bus, making an 81.92kWh bank. Series wiring is unsupported, and packs of another brand or a different capacity must not enter the same bank.

What continuous and peak current figures does the 100Ah pack carry?

Continuous charge and discharge runs at 50A, equal to 2560W. The 100A / 5120W number is a brief peak ceiling only; that level cannot be held on a continuous basis.

What cycle count and warranty period apply to the pack?

Rated 6000 cycles at 80% DoD and 25°C, a near-ten-year design horizon, with three years of warranty cover.

Can it replace an older 48V lead-acid bank in an existing Romanian PV system?

As a 48V-class LFP pack it can stand in for an older lead-acid solar bank, provided the inverter is set to the 58.4V bulk/absorption voltage and recognises the matching BMS protocol.

How does the pack mount indoors, and what are its weight and case dimensions?

A steel bracket fixed to the wall with expansion bolts carries the pack. Net 44kg, case 640 H × 428 W × 160 D mm; round LCD, power switch and copper-alloy ring-lug terminals, IP54 for indoor or sheltered placement.

What does the built-in controller monitor and guard against?

The controller watches over-charge, deep discharge, over-current, short circuit, hot and cold extremes and surge voltage, and balances the pack's cells against one another.

What ambient and storage temperatures apply, and may it charge under 0°C?

Use runs from −10°C to 50°C and storage between 0°C and 35°C. No warming element is installed, and charging the cells below 0°C is barred.

Related GSIKE Guides for Romania

Gsike 51.2V 100Ah Wall Battery for Self-Consumption and Backup Under Romanian Household Electricity Conditions

Work through self-consumption rates, the evening household load and reserve assumptions for a 5kWh wall pack under Romanian household conditions.

Best 5kWh Wall LiFePO4 Batteries for 230V Homes: Gsike 100Ah Compared With Certified Rivals in Romania

Compare the FixWall 5.0 with established CE-certified 5kWh wall options on format, communication and warranty positioning.

Sizing a 5.12kWh Gsike Wall Battery for Evening Backup and Self-Consumption During Outages

Map evening household kWh and essential outage loads against the 5.12kWh reserve, and decide how much storage a typical Romanian home needs.

Installing a Gsike 100Ah Wall Battery With a 230V Hybrid Inverter: Wall-Mount and CE/IEC Guide

Review wall-mount checks, communication wiring, charge-profile matching and CE/IEC considerations for a Romanian retrofit installation.

51.2V 100Ah LiFePO4 battery, 48V 100Ah home battery, 5kWh wall mounted battery, 230V hybrid inverter battery, 48V 100Ah 5.12kWh LiFePO4 wall battery, GSIKE FixWall 5.0, 5kWh solar battery for a Romanian home, low-voltage 48V LFP battery for PV storage, wall-mounted LiFePO4 battery with BMS and CAN, 48V 100Ah battery for a 230V solar hybrid inverter, evening self-consumption wall battery for Romania, 5kWh backup pack for apartment, family house and village home